Cos Programming; Toll Restriction Level -- Day / Night - Panasonic KX-TA1232 Programming Manual

Advanced hybrid system
Hide thumbs Also See for KX-TA1232:
Table of Contents

Advertisement

General Programming

2.6 COS Programming

[500]-[501] Toll Restriction Level —— Day / Night
Description
Each extension must be assigned a Class of Service (COS). These programs set the toll
restriction value for each COS in day or night mode.
Selection
• COS number: 1 through 8,
• Level number: 1 through 8
Default
COS 1 through 7 — Level 1 —— Day / Night;
COS 8 — Level 7 —— Day / Night
Programming
1.
Enter a program address (500 for day or 501 for night).
Display example: 500 TRS DAY LVL
2.
Press NEXT.
Display: COS NO?
3.
Enter a COS number.
To enter COS number 1, you can also press NEXT.
Display example: COS1:1
4.
Enter a level number.
To change the current entry, press CLEAR and enter the new number.
5.
Press STORE.
6.
To program another COS, press NEXT or PREV, or SELECT and the desired COS
number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
• To assign all COS to one selection, press the
the contents programmed for COS 1.
• Program [601] Class of Service is used to assign a Class of Service to each extension.
138
( =all COS)
key in step 3. In this case, the display shows
Programming Guide