Operation Section
Starting From a 12 Volt External
Source
WARNING
Sparks occurring near the battery could cause
vapors to explode.
Always connect the external power source
ground cable to a point away from and below
the battery, and well clear of fuel system
components.
NOTICE
Do not reverse battery cables. It can cause
damage to the alternator.
Always connect the external power source
cables in parallel with the lift truck battery
cables : POSITIVE(+) to POSITIVE(+) and
NEGATIVE( - ) to NEGATIVE( - ).
Attach ground cable last, remove first. All lift
trucks equipped with DAEWOO built internal
combustion engines are NEGATIVE( - ) ground.