Table a. MI-04 Diagnostic Fault Codes (Flash Codes)
DFC
Probable Fault
56
XDRPSensorInputHigh
+5VDC Transducer power supplied
by the SECM to the sensors is above
+5.20VDC
57
Engine OverSpeed
Engine
RPM
maximum RPM set point
61
Pedal1SensorInputLo
APP1 signal disconnected, open
circuit or sensor malfunction
(Expected
connector is unplugged
CODES: 61 & 66)
62
Pedal1SensorInputHi
APP1 sensor failure or shorted circuit
63
Pedal1SensorRangeLo
APP1
potentiometer
Improper APP1 reading may be due
to dirt or oxidation on the sensor
traces.
64
Pedal1SensorRangeHi
APP1
potentiometer
Improper APP1 reading may be due
to dirt or oxidation on the sensor
traces
increased
beyond
faults
when
APP
malfunction.
malfunction.
Action
Engine Shutdown
Engine Shutdown
MIN Power Limit
MIN Power limit
Stored Fault Code
(MIL Only)
Stored Fault Code
(MIL Only)
-109-
Operation Section
Corrective Action, First Check
Measure transducer power at the
TMAP connector with a multimeter
Verify transducer power at the SECM
with a multimeter
Verify transducer power at ETC with
a multimeter
Verify transducer power to the foot
pedal with a multimeter
Usually associated with additional
ETC faults
Check for ETC Sticking or
other ETC faults
Verify if the lift truck was
motored down a steep grade
Check foot pedal connector
Check foot pedal connector
Check foot pedal connector
Check foot pedal connector