To access Pattern from the Test branch, make the
following selections:
Test :
Pattern
F1
F2
Press the
key until Pattern appears. Select Pattern
to start this test.
Test : Pattern
Blks Errd = xxxxxxx
F1
F2
BlksErrd=xxxxxxx displays the number of blocks of
data found in error (block size is 1000 bits per block). The
message NoSync can appear as a value for BlksErrd while
the modem's receiver is synchronizing. The message
OvrFlw can appear as the value for BlksErrd if the
counter overflows.
Press the
key to display BlksRcvd=xxxxxxx,
number of blocks of data received.
3810-A2-GB30-30
Figure 8-6. End-to-End Pattern Test
>
F3
>
F3
September 1998
The Pattern test can be exited and reentered without
restarting the test. The BlksErrd and BlksRcvd continue
counting.
If the Test Timeout configuration option is enabled,
Test Timeout appears at the conclusion of the test. If it is
disabled, the test operates until aborted. For more
information on the Test Timeout configuration option,
refer to the Tests section of Chapter 9.
To exit this function and remain in the Test branch,
press the
key. To exit and return to the Top-Level
menu, press the
key.
AT Command Equivalent
The AT command for Pattern is &T2.
Test Branch
8-7