Overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
This appendix points out basic problems that can occur
when operating a 3800 Series modem. Use Tables C-1
through C-6 to check out these problems. If you are
having data communication difficulties, such as periodic
Symptom
Modem did not pass
power-up self-test
Power LED does not
light
LCD does not display
A problem is suspected
after the power-up
self-test
3810-A2-GB30-30

Modem Health

Contact your service representative.
Make sure the modem's ON/Off switch is in the ON position.
Make sure the ac power transformer is connected to the ac power receptacle.
If Power LED and/or LCD do not operate, contact your service representative.
Perform a self-test via the modem's DCP or type AT&T9 if using AT commands.
Perform a local analog loopback with a Pattern test. If the modem consistently registers errors,
contact your service representative.
If the modem passes the above tests and a problem still exists, then the problem is likely not
with your modem.
September 1998

Troubleshooting

character loss, random errors, or constant format errors,
use the loopback tests described in Chapter 8, Test
Branch. With these tests you can usually isolate the fault
in your system by using the process of elimination. If
problems continue to occur, contact your service
representative.