E9 Toner Motor Error - Kyocera FS-1800 Service Manual

Hide thumbs Also See for FS-1800:
Table of Contents

Advertisement

(18) E9 Toner motor error
Meaning
Toner motor is
overloaded.
TNMOC is detected by
sampling every other
100 ms in 2 seconds
since the main and
toner motors are
activated following the
Replace toner
Clean printer
message after
the Toner low
TK-60 is detected.
FS-1800/1800N | FS-3800/3800N
Suggested causes
• Overcurrent in the toner motor circuitry due
to an excessive torque, caused by hardened
toner.
• Defective gate array U204 on the engine
board.
• Improper connector insertion.
• Defective harness between developer and
high voltage unit.
• Defective harness between high voltage unit
and engine board.
Call service
personE9:0123456
Replace with a new
toner kit. See page 3-4.
Yes
"E9"
shown?
No
End.
NOTE:
If the problem is not solved by
this flow chart, replace the
following items:
High voltage unit
Harness (S02416) [Between developer and high voltage unit]
Harness (S02416) [Between engine board and high voltage unit]
Replace engine board
(KP-864) and developer.
See page 5-22 and 3-13.
6-22
Corrective action
Follow the flow chart
below.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-3800

Table of Contents