Step 7.2 U-Tube Hanger Placement
Bow
Shackle
Suspension
Chain
Washers
Bolt
(Torque:
13.5 Nm
129 in lb)
Configuration
First Tube and
Reflector Hanger
Description
Bow Shackle
Tube/Reflector Hanger
Spreader Bar
Step 7.3 Burner Tube and Fan Tube Installation
Weld
Spot
Burner Tube
Description
Burner Tube
Fan Tube
Spreader
Bar
Threaded
Bar
Tube and Reflector
Hanger
Optional
Hanging
229 cm ± 25cm
Part Number
E0007576
03090100
07260010
Fan Tube
Part Number
03051100
S5127W
SECTION 7: U-T
UBE
NOTE: Spreader bar must be used on
single suspension point installations.
Do not hang heater from spreader bar.
Bow
Shackle
Suspension
Chain
Tube and Reflector
See Assembly
Drawing
Offset mounting
hole must be
to the top.
Weld seam
must be to the
bottom of the tube.
H
I
EATER
NSTALLATION
Hanger
23