I Ftp Client Setup - Panasonic WV-NW474S Operating Instructions Manual

Color cctv camera
Hide thumbs Also See for WV-NW474S:
Table of Contents

Advertisement

• Click the [SET & REBOOT] button.
Note: Wait for around 10 seconds until rebooting is
completed.
Note: Sending E-mails will not be possible in an envi-
ronment where POP (Post Office Protocol) authenti-
cation is required.
7. External Alarm Reset
• Click the [Alarm Reset] button to cancel the activat-
ed alarm.
Note: Input an external alarm signal of more than
100 ms.

I FTP Client Setup

Image files can be transferred to the FTP server within
the scheduled time zone.
1. Open the FTP Client Setup window.
2. Common Setup
• Enter the FTP server address.
A hostname.domainname can be entered when
using the DNS function.
• Enter the user name in up to 16 characters.
• Enter user name and password in up to 16 char-
acters to access the FTP server.
• Select Sequential or Passive as the transmission
mode.
Passive
Sequential does not perform properly.
• Complete schedule 1 and 2 by specifying the
transmission time zone and the day of the week.
is
recommended
when
3. Non-Alarm (FTP) Image Transmission Setup
• Select ON or OFF to transmit ordinary image files
except in an alarm condition.
ON: Transmits files when a scheduled time
comes.
OFF: Does not transmit, and no schedule is
applied.
• Enter the receiver directory. The column should
not be empty.
• Enter the file name and click FIX or DATE.
FIX: Uses repeatedly a single file name when
overwriting new data.
DATE: Creates and attaches a serial number
and a date-and-time to the entered file name.
• Select the transmission interval by pressing the
[o] button.
Available times (seconds): 0.2 - 0.9, 1 - 1 440
Available times (minutes): 1 - 1 440
Notes:
• The transmission may be longer due to the net-
work speed and/or traffic conditions.
• An alarm image precedes a non-alarm image in
transmission to the FTP server. The non-alarm
image may not be sent when alarm activations
frequently arise.
4. Alarm (FTP) Image Transmission Setup
The alarm setup window specifies the profile of the
file transmission such as the number of files and the
frame rate (fps).
• Select ON or OFF to transmit the image files.
ON: Transmits the files when alarm arises.
OFF: Does not transmit.
• Enter the receiver directory. The column should
not be empty.
• Enter the file name. The column should not be
empty.
5. Click the [SET & REBOOT] button.
Note: Wait for around 10 seconds until rebooting is
complete.
Note: Set the file system on the FTP server to the
UNIX mode when using the FTP client function.
-38-

Advertisement

Table of Contents
loading

Table of Contents