WlETHOD FUR STANDARD WALLS
1.
Dis-assemble
Manifold
from Sleeve.
The
flue
consists
of 3 parts,
sleeve,
inside
connectors
and
tube,
outside
terminal;
(dis-assemble
by pulling
hard on
outside
terminal
and inner
connections,
then pull sleeve
off outer terminal).
Co""Gctio"s
sleeve
Ter Final
2.
Adjustment
of Sleeve
Length.
Measure
wall
thickness
through
Extension joint
previously
drilled
80 mm hole.
under plastic
Extension
End of sleeve
should
protrude
5-10
mm
from outside
wall. Adjust
sleeve
length
to
("A" and "AA" flues only)
wall thickness
plus 5 -10 mm. (Sleeve
is
ve.
threaded
for adjustment).
3.
For A and AA flues
only
Depending
on flue set and wall thickness
extension
piece
"C"
may
need
to be
removed.
Cut plastic,
remove
extension,
then follow
instruction
2.
This applies
to "A" and "AA" flues
only.
There
isno
extension
on other flues, they
can be fully
adjusted
by turning
the
threaded
section.
Remove extension
at this
pointif necessary.
4.
Fixing
Sleeve.
Fix to the
wall,
using
the
3 screws
5-10 mm
provided.
NOTE:
The
flange
is marked
"TOP",
sleeve
must be fitted
with this mark UP.
Check
sleeve
protrudes
5-10
mm on
the outside.
Don'1 remove green plastic covering from sleeve.