Fiber Optic Ethernet Port Specifications; Operating Environment - Siemens RUGGEDCOM RS900G Installation Manual

Hide thumbs Also See for RUGGEDCOM RS900G:
Table of Contents

Advertisement

Chapter 4
Technical Specifications
Section 4.3

Fiber Optic Ethernet Port Specifications

The following details the specifications for fiber Ethernet ports that can be ordered with the RS900G.
NOTE
• Maximum segment length is greatly dependent on factors such as fiber quality, and the number
of patches and splices. Consult a Siemens Sales associate when determining maximum segment
distances.
• All optical power numbers are listed as dBm averages. To convert from average to peak add 3 dBm.
To convert from peak to average, subtract 3 dBm.
• All cabling is duplex type unless otherwise specified.
Connector
Mode
Type
MM
LC
SM
LC
SM
LC
SM
SC
SM
SC
MM
LC
SM
LC
SM
LC
d
SM
LC
d
SM
LC
SM
SC Simplex
d
SM
SC Simplex
c
Typical.
d
Utilizes a distributed feedback (DFB) type laser. Rated for -20 to 85 °C (-4 to 185 °F) operation only.
Section 4.4

Operating Environment

Parameter
Ambient Operating Temperature
Ambient Relative Humidity
Ambient Storage Temperature
18
Cable
c
Tx λ (nm)
Type (μm)
50μ/125
850
9μ/125
1310
9μ/125
1310
9μ/125
1310
9μ/125
1310
50μ/125
850
9μ/125
1310
9μ/125
1310
9μ/125
1550
9μ/125
1550
9μ/125
1310
9μ/125
1490
Range
-40 to 85 °C
(-40 to 185 °F)
5% to 95%
-40 to 85 °C
(-40 to 185 °F)
Tx min
Tx max
(dBm)
(dBm)
-9.5
-4
-9.5
-3
-5
0
-10
-3
-7
-3
-8.5
-4
-9
-3
-7
-3
-5
0
0
5
-9
-3
-9
-3
Comments
Measured from a 30 cm (12 in) radius surrounding the center of the
RS900G enclosure.
Non-condensing
RUGGEDCOM RS900G
Installation Guide
Rx
Rx
Sensitivity
Saturation
(dBm)
(dBm)
-20
0
-22
-3
-22
-3
-22
-3
-24
-3
-22
-3
-24
0
-26
-3
-26
0
-26
0
-22
-3
-22
-3
Fiber Optic Ethernet Port Specifications
Distance
c
(km)
0.5
10
25
10
25
0.5
10
25
50
80
10
10

Advertisement

Table of Contents
loading

Table of Contents