Sfp Optic Ethernet Ports; Installing An Sfp Optical Port - Siemens RUGGEDCOM RS900G Installation Manual

Hide thumbs Also See for RUGGEDCOM RS900G:
Table of Contents

Advertisement

Chapter 3
Communication Ports
1
Figure 10: SC Port
1. Tx Connector
2. Rx Connector
For specifications on the available fiber optic Ethernet ports, refer to
Specifications".
Section 3.2

SFP Optic Ethernet Ports

SFP (Small Form-Factor Pluggable) optic Ethernet ports are available with LC (Lucent Connector) connectors.
Make sure the Transmit (Tx) and Receive (Rx) connections of each port are properly connected and matched to
establish a proper link.
Figure 12: LC Port
1. Tx Connector
2. Rx Connector
NOTE
SFP modules, as well as their optical ports, can be safely inserted and removed while the chassis is
powered and operating.
The following sections describe how to install and remove SFP optical ports:
Section 3.2.1, "Installing an SFP Optical Port"
Section 3.2.2, "Removing an SFP Optical Port"
Section 3.2.1

Installing an SFP Optical Port

To install an SFP optical port, do the following:
CAUTION!
Electrical hazard – risk of damage to equipment. Use only components certified by Siemens with
RUGGEDCOM products. Damage to the module and device may occur if compatibility and reliability
have not been properly assessed.
14
2
Figure 11: LC Port
1. Tx Connector
Section 4.3, "Fiber Optic Ethernet Port
1
2
Installation Guide
1
2
2. Rx Connector
SFP Optic Ethernet Ports
RUGGEDCOM RS900G

Advertisement

Table of Contents
loading

Table of Contents