[10] System Event (Strobe Output)
The output activates when any of the selected system events
(alarms) occur on the system.
This output will activate for silent and audible
alarms or medical conditions only. It will not
activate during pre-alert or delays.
If attribute [8] is turned ON, the output will activate for the
number of seconds programmed in the PGM output timer
(section [164]).
If attribute [8] is turned OFF, in the armed state, the output will
deactivate only once the system is disarmed. If an alarm activates
this output in the disarmed state, the output will deactivate if a
user enters a valid access code while the Bell Cut-off timer is
counting down. The output will also deactivate if someone arms
the system after the Bell Cut-off has expired.
This output can be used to indicate that an alarm has occurred
before entering the premises.
The PGM attributes for this option, programmed in Sections
[141] to [142], differ from the standard selection of attributes.
Program which events will activate the output by selecting
some or all of the following attributes:
Attribute
[1] ........ Burglary (Delay, Instant, Interior, Stay/Away and
24 Hour Burglary Zones)
[2] ........ Fire (Fire Keys, Fire Zones)
[3] ........ Panic (Panic Keys and Panic Zones)
[4] ........ Medical (Auxiliary Keys, Medical and Emergency
Zones)
[5] ........ Supervisory (Supervisory, Freezer and Water
Zones)
[6] ........ Priority (Gas, Heat, Sprinkler and 24 Hour
Latching Zones)
[7] ........ Holdup (Holdup zones)
[8] ........ Output Follows Timer / Output Latched (output
will activate for the number of seconds
programmed in the PGM Output Timer)
If attribute [8] is turned ON, attributes [1-7] must
also be turned ON.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
PGM Output Timer ............................................ Section [164]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
[11] System Tamper (All Sources)
The PGM output will activate when any tamper condition is
present and will deactivate when all tampers are restored.
[12] TLM and Alarm
The PGM output activates when the system experiences both a
telephone line trouble and an alarm. When the system is armed,
the output will deactivate only if an access code is entered or
if the telephone line is restored with the system is in an armed
or disarmed state.
If an alarm activates this output in the disarmed state, the output
will deactivate if a user enters a valid access code while the Bell
Cut-off timer is counting down. The output will also deactivate
if someone arms the system after the Bell Cut-off has expired.
This output will activate for all silent and audible
alarms except the Duress alarm.
R
A
M
D
E
S
C
[13] Kissoff Output
The output will activate for two seconds after the control panel
receives the kissoff transmission from the central station.
[14] Ground Start Pulse
The PGM Output will activate for two seconds to obtain a dial tone
on Ground Start telephone equipment before the panel attempts
to dial. Two 2-second pauses should be inserted at the beginning
of the telephone number when using this option.
[15] Remote Operation (DLS-1 Support)
This output can be activated and deactivated remotely using
the DLS software.
[16] LINKS1000 Support (PGM1 Only)
The PGM output will be used as a data wire to communicate
telephone number information for the LINKS1000 cellular unit.
[17] Away Armed Status
When the system is armed in the Away mode, the PGM output
will activate at the beginning of the exit delay. The output
deactivates when the panel is disarmed.
[18] Stay Armed Status
When the system is armed in the Stay mode, the PGM output will
activate at the beginning of the exit delay. The output deactivates
when the panel is disarmed.
[19] [ ] [7] [1] Command Output Option #1
[20] [ ] [7] [2] Command Output Option #2
These outputs are user-initiated by entering [ ] [7] [1-2] at any
keypad. When any output is activated, three acknowledgment
beeps are heard.
NOTES on Option [20] [ ] [7] [2]:
Press [ ] [7] [2] [Access Code, if required] to activate any
output programmed as one of PGM output option [03] or [20].
Traditionally, [ ] [7] [2] has been reserved for resetting smoke
detectors. Smoke detectors should now be programmed as
output [03] "Sensor Reset".
Only ONE of options [03] Sensor Reset and [20] [ ]
[7] [2] Command Output Option #2 may be pro-
grammed on the same system.
[21]-[24] For Future Use

PGM Output Attributes

In addition to programming the output type, you must also
program the PGM output attributes for each output.
PGM output options [09] "System Trouble" and [10] "System
Event" have their own unique set of attributes listed below the
description of each output type.
PGM output options [01], [03], [05]-[08], [11]-[20] have the
following attributes:
Attribute
[1] ........... Output Enabled
[3] ........... True Output
[4] ........... Output Pulsed
21
R
I
P
T
ON
OFF
Disabled
Inverted Output
Attribute ON: the output energizes when activated
Attribute OFF: the output de-energizes when
activated
Output ON/OFF
Attribute ON: the output will activate once for the
amount of time programmed in section [164]
when initiated by the user
Attribute OFF: the output will turn ON and OFF
when initiated by the user.
(only applicable to options [19]-[20])