[014] Second System Option Code
Default
Option
OFF
I _ _ ______I
OFF
I _ _ ______I
OFF
I _ _ ______I
OFF
I _ _ ______I
OFF
I _ _ ______I
ON
I _ _ ______I
OFF
I _ _ ______I
OFF
I _ _ ______I
[015] Third System Option Code
Default
Option
ON
I _ _ ______I
OFF
I _ _ ______I
OFF
I _ _ ______I
ON*
I _ _ ____ __I
OFF
I _ _ ______I
OFF
I _ _ ______I
ON
I _ _ ______I
OFF
I _ _ ______I
* When using a PC5132 version 2.1 or older with WLS909 Wireless Keys, option [4] must be ON for the arm button to
work.
[016] Fourth System Option Code
Default
Option
ON
I _ _ ______I
OFF
I _ _ ____ __I
OFF
I _ _ ______I
OFF
I _ _ ______I
ON
I _ _ ______I
OFF
I _ _ ______I
OFF
I _ _ ______I
OFF
I _ _ ______I
[017] Fifth System Option Code
Default
Option
ON
I _ _ ______I
OFF
I _ _ ____ __I
[020] Keypad Zone Assignments
(Section 2.12 "Keypad Zones")
Only one keypad may be assigned to any given zone.
Default
00
I _ _ ______I _ ______I
00
I _ _ ______I _ ______I
00
I _ _ ______I _ ______I
00
I _ _ ______I _ ______I
00
I _ _ ______I _ ______I
00
I _ _ ______I _ ______I
00
I _ _ ______I _ ______I
00
I _ _ ______I _ ______I
R
A
M
M
I
ON
1
Arm / Disarm Bell Squawk enabled
2
Bell Squawk During Auto Arm
3
Bell Squawk On Exit Delay
4
Bell Squawk On Entry Delay
5
Bell Squawk On Trouble
6
Audible Exit with Urgency
7
Exit Delay Termination Enabled
8
Fire Bell is Continuous
ON
Fire Keys Enabled
1
2
Panic Keys Audible (Bell / Beeps)
3
Quick Exit Enabled
4
Quick Arming Enabled
5
Code Required For Bypassing
6
Master Code Not Changeable
7
TLM Enabled
8
TLM Audible (Bell) When Armed
ON
1
AC Trouble Displayed
2
Trouble Light Flashes if AC Fails
3
Blank Keypad When Not Used
4
Code Required to Remove Kypd Blanking No Code Required
5
Keypad Backlighting is enabled
6
Power Save Mode enabled
7
Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed
8
Keypad Tampers enabled
ON
1
Unident. Wireless Key Disarm Enabled Disabled
2-8
For Future Use
Keypad (Slot 1) Zone
Keypad (Slot 2) Zone
Keypad (Slot 3) Zone
Keypad (Slot 4) Zone
Keypad (Slot 5) Zone
Keypad (Slot 6) Zone
Keypad (Slot 7) Zone
Keypad (Slot 8) Zone
N
G
W
O
OFF
Arm / Disarm Bell Squawk disabled
No Bell Squawk During Auto Arm
No Bell Squawk On Exit Delay
No Bell Squawk On Entry Delay
No Bell Squawk On Trouble
Silent Exit Delay
Exit Delay Termination Disabled
Fire Bell follows Bell Cut-off
OFF
Fire Keys Disabled
Panic Keys Silent
Quick Exit Disabled
Quick Arming Dis. / Function keys Req. Code3.4
No Code Required
Master Code Changeable
TLM Disabled
TLM Trouble Beeps When Armed
OFF
AC Trouble Not Displayed
Trouble Light Does Not Follow AC Status
Keypad Active Always
Keypad Backlighting is disabled
Power Save Mode disabled
Keypad Tampers disabled
OFF
Valid entries are zones 01-08
Valid entries are zones 01-08
Valid entries are zones 01-08
Valid entries are zones 01-08
Valid entries are zones 01-08
Valid entries are zones 01-08
Valid entries are zones 01-08
Valid entries are zones 01-08
30
R
K
S
H
E
E
T
S
Section
5.17
5.18
5.18
5.18
3.4
5.18
5.18
5.13
Section
5.16
5.16
3.4
3.4
5.1
5.12
5.12
Section
3.4
3.4
5.22
5.22
5.23
5.22
5.17
5.25
Section
5.17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents