Broan rmdd3004 Instruction Manual page 8

Downdraft
Table of Contents

Advertisement

Available languages

Available languages

INSTALL ELECTRICAL WIRING
Internal Blower Installation
CAUTION: All electrical wiring should be done
!
by a qualified person(s) in accordance with all
applicable codes and standards.
1. Mount a standard wiring box, with 3-pronged receptacle, inside
the cabinet. Make sure the downdraft's power cord can easily
reach it.
2. Run appropriate power cable into cabinet and connect it to
receptacle.
3. Plug the downdraft's power cord into the outlet. Make sure that
the power cord is routed away from the heat generated by the
cooktop.
INSTALL COOKTOP
All Units
1. Align the cooktop with the downdraft and fasten cooktop in
place.
Note: Accurate alignment of cooktop and downdraft is necessary
to ensure that there is no interference when air vent is raised and
lowered. There should be a gap of 1/32" - 1/16" between the back
of the cooktop and the front of the downdraft cover.
External Blower Installation
CAUTION: All electrical wiring should be done
!
by a qualified person(s) in accordance with all
applicable codes and standards.
1. Mount a standard wiring box, with 3-pronged grounded recep-
tacle, inside the kitchen cabinet. Make sure the unit's power
cord can easily reach it.
2. Run appropriate power cable into cabinet and connect it to
electrical box and receptacle.
3. External blower may not exceed 6.0 Amp rating.
4. Run 2-wire plus ground power cable from the external blower
to wiring box on adaptor plate. Remove wiring box cover.
5. Connect wiring harness to power cable from external blower.
Wire black to black, white to white, and green to green or bare
wire.
6. Replace wiring box cover.
7. Plug the downdraft's power cord into outlet. Make sure that
the power cord is routed away from the heat generated by the
cooktop.
COOKTOP
Note:
The downdraft up/down control must be mounted into the coun-
tertop, at least 4" from the cooktop.
Downdraft Ventilators
UP / DOWN
CONTROL
COUNTERTOP
Page 8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rmdd4804Rmdd3604Rmdd3004exRmdd3604exRmdd4804ex

Table of Contents