Broan RM326H Manual

Broan RM326H Manual

Internal blower
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

INTERNAL BLOWER
(for use with RM60000 Series Range Hoods)
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSON(S) OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent power
from being switched on accidentally. When the service discon-
necting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by qualified
personnel in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting.Follow the heating equipment
manufacturer's guidelines and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this range hood with any additional solid-state
speed control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking flaming foods.
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
NOTE: This blower is compatible with older "60000
Series" Rangemaster
lation instructions included with the hood, visit
www.broan.com, or contact Technical Support.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE
EVENT OF A RANGE TOP GREASE FIRE,OBSERVE THE
FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN – You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels – This
could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you know
how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. This blower has a thermal overload which will automatically
shut off the motor if it becomes overheated.The motor will
restart when it cools down.If the motor continues to shut off
and restart, have the hood serviced.
4. Please read specification label on product for further informa-
tion and requirements.
5. To reduce the risk of fire and to properly exhaust air on a ducted
installation, be sure to duct air outside – Do not exhaust air
into spaces within walls or ceiling or into attics, crawl spaces,
or garage.
INSTALLER:
Save this manual for Electrical Inspector
and Homeowner to use.
MODEL RM326H
Page 1
®
Hoods. Refer to the instal-

Advertisement

Table of Contents
loading

Summary of Contents for Broan RM326H

  • Page 1 Series” Rangemaster Hoods. Refer to the instal- (for use with RM60000 Series Range Hoods) lation instructions included with the hood, visit www.broan.com, or contact Technical Support. WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE...
  • Page 2 MODEL RM326H Page 2 MODEL 441 MODEL 437 (10’’ Round wall cap) (High capacity roof cap) Wall & Roof Caps, Exterior Blowers MODEL 418 (10” round adjustable elbow) Elbows MODEL 410 Ductwork (10” round duct—2 ft. sections) MODEL 421 In-Line (10”...
  • Page 3: Installation

    MODEL RM326H Page 3 INSTALLATION VERTICAL DISCHARGE ROUGH-IN PLATE BLACK TO BLACK WHITE TO WHITE GREEN TO GREEN MOUNTING OR BARE WIRE TO MOUNTING STUDS STUDS GROUND SCREW COVER PLATE NUTS Remove wiring cover. ROUGH-IN Run power cable to installation location, remove knockout...
  • Page 4 MODEL RM326H Page 4 ROUGH-IN MOUNTING STUDS PLATE PLATE HOOD RECEPTACLE ROUGH-IN PLATE POWER CORD SLOTS HOOD RECEPTACLE BLOWER POWER TABS CORD BLOWERS BLOWER / MOUNTING PLATE ASSEMBLY HEX NUTS (2) Attach BLOWERS to MOUNTING PLATE with (8) 10 -24 HEX NUTS.
  • Page 5: Service Parts

    MODEL RM326H Page 5 SERVICE PARTS Model P12 ROUGH IN PLATE PART DESCRIPTION NUMBER 97018167 ROUGH-IN PLATE WELDMENT 97018827 MOUNTING PLATE ASSEMBLY 99440033 POWER CORD 99150471 SCREW, #10-32 X 1/2 HEX WASHER HEAD* 99400060 STRAIN RELIEF 98003370 OUTLET BOX COVER...
  • Page 6 NOTE: Ce ventilateur est compatible avec une série ® plus ancienne de 60000 hottes de Rangemaster (pour utilisation avec les hottes de cuisine de Référez-vous aux instructions d’installation incluses avec le capot, visitez www.broan.com, ou entrez en série RM60000) contact avec l’appui technique. AVERTISSEMENT AVERTISSEMENT A F I N D E D I M I N U E R L E S R I S Q U E S D ’...
  • Page 7 MODÈLE RM326H Page 7 MODÈLE 437 MODÈLE 441 (capuchon de toit – grande capacité) (capuchon mural rond de 25 cm [10 po]) Capuchon mural et de toit, ventilateurs extérieurs MODÈLE 418 Coudes (coude rond ajustable de 25 cm [10 po]) MODÈLE 410...
  • Page 8 MODÈLE RM326H Page 8 INSTALLATION ÉVACUATION VERTICALE PLAQUE DE RACCORDEMENT NOIR AVEC NOIR BLANC AVEC BLANC CONNECTEZ LE FIL VERT OU LE FIL DÉNUDÉ À LA VIS GOUJONS DE MISE À LA TERRE GOUJONS DE MONTAGE DE MONTAGE PLAQUE DE FERMETURE ÉCROUS...
  • Page 9 MODÈLE RM326H Page 9 PLAQUE DE PLAQUE DE RACCORDEMENT MONTAGE GOUJONS RÉCEPTACLE DE HOTTE CORDON ÉLECTRIQUE DE LA PLAQUE DE RACCORDEMENT FENTES RÉCEPTACLE DE HOTTE CORDON ÉLECTRIQUE ERGOTS DU VENTILATEUR VENTILATEURS ENSEMBLE DE VENTILATEUR / PLAQUE DE MONTAGE ÉCROUS HEXAGONAUX (2) ÉCROUS HEXAGONAUX (8)
  • Page 10: Pièces De Rechange

    MODÈLE RM326H Page 10 PIÈCES DE RECHANGE Model P12 PLAQUE DE RACCORDEMENT R EPÈRE N° DE DESCRIPTION QTÉ PIÈCE 97018167 PLAQUE DE RACCORDEMENT SOUDÉE 97018827 ENSEMBLE DE PLAQUE DE MONTAGE 99440033 CORDON ÉLECTRIQUE 99150471 VIS, N° 10-32 X 1/2 TÊTE HEXAGONALE À...
  • Page 11 NOTA: Esto soplador es compatible con una más vieja serie del ® 60000 campanas de Rangemaster . Re era a las instrucciones (Para usarse con las campanas de estufa de instalación incluidas con la campana, visite www.broan. serie RM60000) com, o entre en contacto con la ayuda técnica. ADVERTENCIA ADVERTENCIA...
  • Page 12 MODELO RM326H Página 12 MODELO 437 MODELO 441 (tapa de pared redonda de 10 pulg. [25 cm]) (tapa de techo de alta capacidad) Tapas de pared y techo, ventiladores exteriores MODELO 418 Codos (codo redondo ajustable de 10 pulg. [25cm])
  • Page 13: Instalación

    MODELO RM326H Página 13 INSTALACIÓN DESCARGA VERTICAL PLACA DE EMPALME NEGRO A NEGRO BLANCO A BLANCO VERDE A VERDE O SIN FORRO AL MONTANTES MONTANTES DE MONTAJE TORNILLO DE TIERRA DE MONTAJE PLACA DE CUBIERTA TUERCAS HEXAGONALES Quite la cubierta de la conexión eléctrica.
  • Page 14 MODELO RM326H Página 14 PLACA DE PLACA DE EMPALME MONTAJE MONTANTES RECEPTACULO DE CAMPANA CABLE ELÉCTRICO DE LA PLACA DE EMPALME RANURAS RECEPTACULO DE CAMPANA CABLE ELÉCTRICO LENGÜETAS VENTILADOR VENTILADORES CONJUNTO DE PLACA DE MONTAJE/ VENTILADOR TUERCAS HEXAGONALES (2) Fije los VENTILADORES a la PLACA DE MONTAJE con TUERCAS HEXAGONALES (8) ocho (8) TUERCAS HEXAGONALES 10-24.
  • Page 15: Piezas De Servicio

    MODELO RM326H Página 15 PIEZAS DE SERVICIO Modelo P12 PLACA DE EMPALME C LAVE NÚMERO DESCRIPCIÓN CDAD. N.º DE PIEZA 97018167 ESTRUCTURA SOLDADA DE LA PLACA DE EMPALME 97018827 CONJUNTO DE LA PLACA DE MONTAJE 99440033 CABLE ELÉCTRICO 99150471 TORNILLO, CABEZA DE ARANDELA...
  • Page 16: Warranty / Garantie / Garantía

    MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING.

Table of Contents