Electrical data

RXG+FTXG-E
Representative unit combination
Indoor unit
Outdoor unit
FTXG25EV1BW
RXG25E2V1B
FTXG25EV1BS
RXG25E2V1B
SYMBOLS
MCA
: Min. Circuit Amps (A)
MFA
: Max. Fuse Amps (A)
RLA
: Rated Load Amps (A)
OFM
: Outdoor Fan Motor
IFM
: Indoor Fan Motor
FLA
: Full Load Amps (A)
W
: Fan Motor Rated Output (W)
RHz
: Rated operating frequency(Hz)
• Outdoor Units • R-410A • RXG-E2V1B
Power supply
Hz-volts
50 - 220
Max. 50Hz 264V
50 - 230
Min. 50Hz 198V
50 - 240
50 - 220
Max. 50Hz 264V
50 - 230
Min. 50Hz 198V
50 - 240
• Split Sky Air • Outdoor Units
Vol t age range
MCA
MFA
RHz
12
15
49
12
15
49
NOTES
1
RLA is based on the following conditions:
Indoor temperature 27°CDB/19°CWB
Outdoor temperature 35°CDB
2
Maximum allowable voltage variation between phases is 2%
3
Select wire size based on the larger value of MCA.
4
Instead of fuse, use circuit breaker
5
For more details concerning conditional connections, see
http://extranet.daikineurope.com, select ''E-Data Books''.
Finally, click on the document title of your choice.
Comp.
OFM
IFM
RLA
W
FLA
W
3.3
0.23
3.2
35
0.22
40
3.1
0.21
3.3
0.23
3.2
35
0.22
40
3.1
0.21
3D045220B
FLA
0.52
0.50
0.48
3
0.52
0.50
0.48
5