• Outdoor units for pair application • Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall. • Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency •...
• Outdoor Units • R-410A • RXG-E2V1B Specifications 2-1 NOMINAL CAPACITY AND NOMINAL INPUT RXG25E2V1B RXG35E2V1B Indoor Units FTXG25EV1BW FTXG35EV1BW combination indoor units + outdoor units Nominal Cooling Minimum Capacity Standard Maximum kW Heating Minimum Standard Maximum kW Cooling 4.03 3.30...
• Outdoor Units • R-410A • RXG-E2V1B Electrical data RXG+FTXG-E Representative unit combination Power supply Comp. Indoor unit Outdoor unit Hz-volts Vol t age range 50 - 220 0.23 0.52 Max. 50Hz 264V FTXG25EV1BW RXG25E2V1B 50 - 230 0.22 0.50 Min.
Page 7
• Outdoor Units • R-410A • RXG-E2V1B Electrical data RXG+FTXG-E Representative unit combination Power supply Comp. Indoor unit Outdoor unit Hz-volts Vol t age range 50 - 220 0.23 0.52 Max. 50Hz 264V FTXG35EV1BW RXG35E2V1B 50 - 230 0.22 0.50 Min.
• Outdoor Units • R-410A • RXG-E2V1B Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing unit (mm) RXG25-35E Wall height on air outlet side = less Minimum space for air passage than 1200 Drain outlet 4 x holes for anchor bolts (M8 or M10) (I.D.
• Outdoor Units • R-410A • RXG-E2V1B Dimensional drawing & centre of gravity 5 - 2 Centre of gravity RXG25-35E 4D044107F • Split Sky Air • Outdoor Units...
• Outdoor Units • R-410A • RXG-E2V1B Piping diagram RXG25-35E Outdoor unit Heat exchanger Outdoor temperature thermistor Heat exchanger thermistor Motor operated valve Filter Muffler with Muffler with filter filter Propeller fan Four way valve on : heating Field piping...
• Outdoor Units • R-410A • RXG-E2V1B Wiring diagram 7 - 1 Wiring diagram RXG25-35E Field wiring Indoor Outdoor Note 1. Refer to the name plate for the power requirements. In case of cooling In case of heat pump : Protective earth...
• Outdoor Units • R-410A • RXG-E2V1B Sound data 8 - 1 Sound pressure spectrum RXG25E (Heating) RXG25E (Cooling) approximate approximate threshold hearing for threshold hearing for continuous noise continuous noise Octave band center frequency (Hz) Octave band center frequency (Hz)
• Outdoor Units • R-410A • RXG-E2V1B Operation range RXG25-35E Cooling Heating Indoor temp. (°CWB) Indoor temp. (°CDB) Notes: The graphs are based on the following conditions: + Equivalent piping length 7.5 m + Level difference + Air flow rate...
Page 16
Daikin Europe N.V. explicitly rejects any liability for any direct Daikin Europe N.V. is approved by LRQA for its Quality Daikin Europe N.V. is participating in the or indirect damage, In the broadest sense, arising from Management System in accordance with the ISO9001 EUROVENT Certification Programme.