Frequently asked questions
Problem
There is a build-up of
condensed water in the
drum.
34
Possible cause
There is more than one
tumble dryer vented
together.
Remedy
– The dryer must only be
connected to a joint
ducting system if a
non-return flap is in
place.
– Check the non-return
flap regularly for
damage, and replace it
if necessary.