Normal Function Of The Air Conditioner; A White Mist Coming Out From The Indoor Unit; Low Noise Of The Air Conditioner; Dust Is Blown Out From The Indoor Unit - Vivax ACP-09CH25AEFI User Manual

Table of Contents

Advertisement

Normal function of the air conditioner

The following events may occur during normal
operation. 1. Protection of the air conditioner.
Compressor protection
The compressor can't restart for 3-4 minutes after it stops.
Anti-cold air (Cooling and heating models only)
The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is
in one of the following three situations and the set temperature has not been reached.
a)
When heating has just started.
b)
Defrosting.
c)
Low temperature heating.
The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).
Defrosting (Cooling and heating models only)
Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is
low and humidity is high resulting in lower heating efficiency of the air conditioner.
During this condition air conditioner will stop heating operation and start defrosting
automatically. The time to defrost may vary from 4 to 10 minutes according to the outdoor
temperature and the amount of frost built up on the outdoor unit.

2. A white mist coming out from the indoor unit

A white mist may generate due to a large temperature difference between air inlet and air
outlet on COOL mode in an indoor environment that has a high relative humidity.
A white mist may generate due to moisture generated from defrosting process when the air
conditioner restarts in HEAT mode operation after defrosting.

3. Low noise of the air conditioner

You may hear a low hissing sound when the compressor is running or has just stopped running.
It is the sound of the refrigerant flowing or coming to a stop.
You can also hear a low "squeak" sound when the compressor is running or has just
stopped running. This is caused by heat expansion and cold contraction of the plastic parts
in the unit when the temperature is changing.
A noise may be heard due to louver restoring to its original position when power is turned on.

4. Dust is blown out from the indoor unit.

This is a normal condition when the air conditioner has not been used for a long time or during
first use of the unit.
5. A peculiar smell comes out from the indoor unit.
This is caused by the indoor unit giving off smells permeated from building material, from
furniture, or smoke.
6. The air conditioner turns to FAN only mode from COOL or HEAT mode (For cooling and
heating models only) .
When indoor temperature reaches the temperature setting on air conditioner, the compressor will
stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again
when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and
heating models only) to the set point.