Terminal Description - Siemens SIMOTRAS 6SG7050 Operating Instructions Manual

6sg70 series
Table of Contents

Advertisement

Connections
6.7.3

Terminal description

WARNING
The converter might sustain serious or irreparable damage if connected incorrectly.
The power cables and/or busbars must be secured mechanically outside the converter.
Power section
D400 / 60 -180 Mre converters
D400 / 225 -360 Mre converters
D400 / 525 -680 Mre converters
D400 / 900 Mre converters
The converters are designed for a permanent power supply connection according to DIN VDE 0160
Section 6.5.2.1.
PE conductor connection: Minimum cross-section 10mm
The connection cross-sections must be determined according to the applicable regulations, e.g.
DIN VDE 100 Part 523, DIN VDE 0276 Part 1000.
Function
Supply input
PE conductor
Motor connection
6-30
Terminal type:
U1, V1, W1: Through-hole for M8 (3x20 copper bus)
U2, V2, W2: Through-hole for M8 (5x20 copper bus)
U1, V1, W1: Through-hole for M10 (5x30 copper bus)
U2, V2, W2: Through-hole for M10 (5x35 copper bus)
Through-hole for M12 (5x60 copper bus)
U1, V1, W1: Through-hole for M12 (10x60 copper bus)
U2, V2, W2: Through-hole for M12 (10x50 copper bus)
2
Connection values/Remarks
Terminal
U1 (L1)
V1 (L2)
W1 (L3)
see technical data in Section 3.4
U2 (T1)
V2 (T2)
W2 (T3)
. (see Section 5.1 for connection options).
SIEMENS AG
SIMOTRAS HD
01.04
6SG7000-0BA76
Operating Instructions