22. IMAGE PROCESSING
22.1.2

AE control

Through the AE control, a density suitable for the original density is automatically selected and the copy is made
properly.
A. Sampling area
(1) While in the platen mode
[1]
Original
[2]
L/100 mm
[3]
L mm
[4]
30 mm
(2) While in the DF mode
[1]
Original
[2]
2.9 mm
[3]
1.5 mm
B. Execution timing
While in the platen print: At the pre-scan before the actual scan when the print or the read starts.
While in the DF print
92
[5]
[7]
[6]
[5]
[2]
[4]
[3]
[4]
[6]
[5]
[4]
[3]
: At the same time as when the original is read.
Theory of Operation Ver.2.0 Mar. 2009
[1]
[2]
[5]
10 mm
[6]
Leading edge of the original
[7]
AE sampling range
[1]
[2]
[4]
20 mm
[5]
Leading edge of the original
[6]
AE sampling range