Display Type - Siemens SIMATIC CP 340 User Manual

Ptp coupling and configuration
Hide thumbs Also See for SIMATIC CP 340:
Table of Contents

Advertisement

Display type

The table below describes the possible display types for the values of the variables. Display
types N and P are exceptions and are explained below the table.
The display type supports both uppercase and lowercase letters.
Table 2- 18
Display types in the conversion statement
Display type
Associated data type
A
DATE, WORD
C
CHAR, BYTE
WORD
DWORD
ARRAY OF CHAR
ARRAY OF BYTE
D
DATE, WORD
F
REAL, DWORD
H
All data types incl.
ARRAY OF BYTE
I
INT, WORD
DINT, DWORD
N
WORD (text number)
(1)
P
INT, WORD
(2)
R
REAL, DWORD
S
STRING
T
TIME, DWORD
(1)
U
BYTE
WORD
DWORD
X
BOOL
BYTE
WORD
DWORD
PtP coupling and configuration of CP 340
Manual, 04/2011, A5E00369892-03
Default display
10.06.1992 (German)
A, B
AB
ABCD
ABCDE ...
ABCDE ...
1996–06–10 (American)
0.123456
In accordance with the
data type
–32767
–2147483647
Message text output
Set page number
0.12E–04
Text output
2d_3h_10m_5s_250ms
255
65535
4294967295
1
11101100
11001... (16)
11001... (32)
Basic Principles of Serial Data Transmission
2.7 Parameterization Data
Width of the default
Description
display
10
German
date format
1
Alphanumeric characters
2
4
10
Date format according to
ICE 61131-3
8
Floating point, without
exponent
In accordance with
Hexadecimal format
the data type
Max. 6
Integer range
Max. 11
Integer 0 to 999
5
8
Floating point, with
exponent
Text strings
Max. 22
Duration (negative
duration is identified by a
leading (-) minus sign)
Max. 3
Integer range, unsigned
Max. 5
Max. 10
1
Binary format
8
16
32
79

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents