Siemens CP 5623 Operating Instructions Manual

Siemens CP 5623 Operating Instructions Manual

Simatic net pg/pc - profibus

Advertisement

CP 5623/CP 5624
SIMATIC NET
PG/PC - PROFIBUS
CP 5623/CP 5624
Operating Instructions
09/2013
C79000-G8976-C281-03
___________________
Preface
___________________
Description of the device
___________________
Software installation
___________________
Hardware installation
___________________
Configuration
___________________
Technical specifications
___________________
Approvals
1
2
3
4
5
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens CP 5623

  • Page 1 ___________________ CP 5623/CP 5624 Preface ___________________ Description of the device ___________________ Software installation SIMATIC NET ___________________ Hardware installation PG/PC - PROFIBUS ___________________ CP 5623/CP 5624 Configuration ___________________ Technical specifications Operating Instructions ___________________ Approvals 09/2013 C79000-G8976-C281-03...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Preface What the consignment contains The following components are supplied with the CP 5623 / CP 5624: ● Communications processor CP 5623 or communications processor CP 5624 ● SIMATIC NET DVD including – SIMATIC NET PC software – Manual Collection ●...
  • Page 4 In addition to the product documentation, the comprehensive online information platform of Siemens Automation Customer Support supports at any time and at any location in the world. You will find the Service & Support pages on the Internet at the following address: (http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo2&aktprim=99&lang=...
  • Page 5 718979&caller=view) SITRAIN - Siemens training for automation and industrial solutions With over 300 different courses, SITRAIN covers the entire Siemens product and system spectrum in the field of automation and drive technology. Apart from the classic range of courses, we also offer training tailored for individual needs and a combination of different teaching media and sequences, for example self-learning programs on CD-ROM or on the Internet.
  • Page 6 Preface CP 5623/CP 5624 Operating Instructions, 09/2013, C79000-G8976-C281-03...
  • Page 7: Table Of Contents

    Table of contents Preface ..............................3 Description of the device ......................... 9 Properties of the CP 5623 ......................9 Properties of the CP 5624 ......................10 PROFIBUS interface ........................11 Meaning of the LED display ......................13 Software installation ..........................15 Installing the SIMATIC NET PC software ..................
  • Page 8 Table of contents CP 5623/CP 5624 Operating Instructions, 09/2013, C79000-G8976-C281-03...
  • Page 9: Description Of The Device

    Description of the device Properties of the CP 5623 Properties The CP 5623 is a communications processor for connecting PCs (personal computers) or PGs (programming devices) to PROFIBUS and MPI networks. The essential properties are as follows: ● Transmission speeds up to 12 Mbps.
  • Page 10: Properties Of The Cp 5624

    The CP 5624 is a communications processor for connecting PCs (personal computers) or PGs (programming devices) to PROFIBUS and MPI networks. In addition to the properties of the CP 5623, the CP 5624 also has the following features: ● Additional PROFIBUS connection as DP slave to a second DP network.
  • Page 11: Profibus Interface

    Use the bus connector with a 180° cable outlet if you want to use the lower PROFIBUS connector (PB2, slave only) or both PROFIBUS connectors at the same time. You can obtain these connectors, for example, under the following order numbers: • 6GK1 500-0FC10 • 6GK1 500-0EA02 CP 5623/CP 5624 Operating Instructions, 09/2013, C79000-G8976-C281-03...
  • Page 12 RTS output signal of the CP module. The control signal is "1" Output active when the device (PG or PC) is sending. Shield The shield is connected to components of the connector housing. CP 5623/CP 5624 Operating Instructions, 09/2013, C79000-G8976-C281-03...
  • Page 13: Meaning Of The Led Display

    Error initializing the module. second flashes quickly: Applies only to Yellow on: Shows polling by the higher-level DP master. DP slave operation Yellow off: DP slave connector is not addressed. with the CP 5624 CP 5623/CP 5624 Operating Instructions, 09/2013, C79000-G8976-C281-03...
  • Page 14 Description of the device 1.4 Meaning of the LED display CP 5623/CP 5624 Operating Instructions, 09/2013, C79000-G8976-C281-03...
  • Page 15: Software Installation

    1. Follow the instructions of the Hardware Wizard of Windows. 2. Do not activate the search for drivers on the Internet. Uninstalling the SIMATIC NET PC software Condition The SIMATIC NET PC software is installed on the PG/PC. CP 5623/CP 5624 Operating Instructions, 09/2013, C79000-G8976-C281-03...
  • Page 16: Alternative Software Packets

    To operate the CP, alternative software packages such as STEP 7 V5.5 or STEP 7 Professional (TIA Portal) are available. You will find current information on this on the Product Support pages under the following entry ID: 47071380 (http://support.automation.siemens.com/WW/view/en/47071380) CP 5623/CP 5624 Operating Instructions, 09/2013, C79000-G8976-C281-03...
  • Page 17: Hardware Installation

    The CP must sit firmly and uniformly in the slot. Check that the module sits firmly in the slot as described in the manual accompanying your PG/PC. Note Oblique installation position is permitted Some PG/PC designs require oblique installation of the CP. This is permitted. CP 5623/CP 5624 Operating Instructions, 09/2013, C79000-G8976-C281-03...
  • Page 18: Installing Hardware

    8. Follow the instructions of the Hardware Wizard of Windows. activate the search for drivers on the Internet. Hardware compatibility Compatibility with predecessor versions The CP 5623 can replace the following predecessor versions: ● CP 5613 A3 ● CP 5613 A2 ● CP 5613...
  • Page 19 Note PCI Express Please note: The CPs of the 5613 / 5614 series are PCI cards. The CP 5623 and CP 5624 communications processors are PCI Express cards. This means that you can only replace previous versions with a CP 5623 / CP 5624 if there is a free PCI Express slot available in the PG/PC.
  • Page 20 Hardware installation 3.3 Hardware compatibility CP 5623/CP 5624 Operating Instructions, 09/2013, C79000-G8976-C281-03...
  • Page 21: Configuration

    13542666 (http://support.automation.siemens.com/WW/view/en/13542666) Compatibility during configuration If there is not yet a CP 5623 / CP 5624 available in the hardware catalog of your STEP 7 version or NCM PC version, you can also select a previous version for configuration. ● For the CP 5623, select a configuration of: –...
  • Page 22 Configuration CP 5623/CP 5624 Operating Instructions, 09/2013, C79000-G8976-C281-03...
  • Page 23: Technical Specifications

    Technical specifications Technical specifications of the CP 5623 / CP 5624 Connection to PROFIBUS Amount For CP 5623 • For CP 5624 • Transmission speeds 9.6 kbps, 19.2 kbps, 45.45 kbps, 93.75 kbps, 187.5 kbps, 500 kbps, 1.5 Mbps, 3 Mbps, 6 Mbps, 12 Mbps...
  • Page 24 Technical specifications Technical specifications of the CP 5623 / CP 5624 Vibration (EN 60068-2-6) 10 to 58 Hz amplitude 0.075 mm 58 to 500 Hz, acceleration 10 m/s Shock (EN 60068-2-27) Half-sine: 50 m/s (5 g), 30 ms Storage and transportation conditions Temperature (EN 60068-2-1+2) -20...+60 °C...
  • Page 25: Approvals

    If the communications processor is part of the equipment of a machine, it must be included in the procedure for obtaining the declaration of conformity by the manufacturer of the machine. C-TICK approval The communications processor meets the requirements of the Australian AS/NZS 3548 standard. CP 5623/CP 5624 Operating Instructions, 09/2013, C79000-G8976-C281-03...
  • Page 26 ● Consult the dealer or an experienced radio/TV technician for help. Siemens AG is not responsible for any radio television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Siemens AG. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.
  • Page 27: Index

    STEP 7, 16, 21 Support, 4 Electric shock, 17 Electrostatic charge, 17 Training, 5 ESD directives, 17 Glossary, 5 LEDs, 13 Mounting, 17 NCM PC, 21 Number of CPs, permitted, 18 Oblique installation position, 17 CP 5623/CP 5624 Operating Instructions, 09/2013, C79000-G8976-C281-03...
  • Page 28 Index CP 5623/CP 5624 Operating Instructions, 09/2013, C79000-G8976-C281-03...

This manual is also suitable for:

Cp 5624

Table of Contents