Other functions

Initializing the unit to
factory default settings
If an error occurs in the CL's internal memory, or if you
forget the password and cannot operate the unit, you can
use the following procedure to initialize the internal
memory.
NOTICE
The entire memory will be deleted if you initialize the
internal memory.
Proceed with the following operation only if you are very
sure you want to do this!
1.
While holding down the SCENE MEMORY
[STORE] key on the panel, turn on the power
to the CL unit.
After the opening screen, the following startup menu
screen will appear.
2.
Press one of the following buttons depending
on the type of initialization you want to
perform.
• INITIALIZE ALL MEMORIES
All memories including scene memories and libraries
will be returned to their initial settings except for
DANTE SETUP.
• INITIALIZE CURRENT MEMORIES
Memories other than scene memories and libraries
will be returned to their initial settings except for
DANTE SETUP.
3.
A dialog box will ask you to confirm the
initialization. Press the INITIALIZE button.
A dialog box will ask you to reconfirm the operation.
4.
Press the OK button in the confirmation
dialog box.
Initialization will begin.
NOTE
Do not press any buttons until initialization is complete.
5.
A message indicates that the initialization
process is complete. Press the EXIT button.
The CL will start up in normal operating mode.
NOTE
• Alternatively, you can continue the operation by selecting a
different menu instead of pressing the EXIT button.
• DANTE SETUP will not be initialized.
Restoring the current scene
to the default state
Turn on the power to the CL unit, and recall (load) the
default setting scene (scene number 000).
NOTE
In the procedure described here, you are asked to recall
this default setting scene so that the remaining step in this
chapter can be performed appropriately. In actual
operation, there is no need to recall the default setting
scene each time.
1.
Turn on the power to the CL unit.
When you turn on the power to the CL, you should
first power-on the CL, and then power-on your power
amp and monitor system. (Reverse this order when
turning the system off.)
NOTE
If a PW800W power supply is connected to the CL, the
power will turn on regardless of whether you first turn on
the power switch of the CL or of the PW800W.
2.
Use the top panel SCENE MEMORY
[INC]/[DEC] keys to make scene number
"000" appear in the SCENE field in the
function access area of the display.
SCENE field
3.
Press the top panel SCENE MEMORY [RECALL]
key.
Scene number "000" will be loaded, and the mix
parameters and bus settings will return to the default
state.
NOTE
Be aware that when scene number "000" is loaded, the
input patch, output patch, internal effect, and HA (Head
Amp) settings will also return to their default state.