NOTE
Although OMNI OUT jacks feature a nominal input/output
level of +4 dBu (maximum level +24 dBu), an internal
switch allows this to be changed to –2 dBu (maximum level
+18 dBu) if necessary. (A fee will be charged for this
procedure.) For details, contact your Yamaha dealer.
8
Dante PRIMARY/SECONDARY connectors
Used to connect to other Dante-compatible network
devices, such as an Rio3224-D I/O device.
Use standard Ethernet cables with Neutrik etherCON
CAT5 compatible RJ-45 plugs.
NOTE
Use STP (shielded twisted pair) cable to prevent
electromagnetic interference. Make sure that the metal
parts of the plugs are electrically connected to the STP
cable shield by conductive tape or comparable means.
9
LINK/ACT Indicators
These indicators show the communication status of
the PRIMARY and SECONDARY connectors.
They flash fast if the Ethernet cables are connected
properly.
0
1G Indicators
These indicators light when the Dante network is
functioning as Giga-bit Ethernet.
A
NETWORK connector
Allows the CL unit to be connected to a computer via
an Ethernet cable (CAT5e or higher recommended).
This connector is used mainly to control mix
parameters or to edit scene memories and libraries
from the dedicated "CL Editor" application program
or "StageMix" iPad application.
NOTE
Use STP (shielded twisted pair) cable to prevent
electromagnetic interference. Make sure that the metal
parts of the plugs are electrically connected to the STP
cable shield by conductive tape or comparable means.
B
SLOT 1–3
Allow for the installation of separately-sold DSP
cards, or mini-YGDAI I/O cards to expand the
number of input/output ports.
C
DC POWER INPUT connector
You can connect the separately-sold PW800W power
supply here as a backup external power supply. If the
PW800W is connected, the CL unit will continue
receiving power from the PW800W, even if its own
internal power supply shuts down due to a problem.
Caution
If you plan to connect the PW800W, be sure to first
power-off both the CL unit and the PW800W. Then, use the
power supply cable (PSL360) to make the connection.
Failure to observe this caution may cause malfunction or
electric shock.
NOTE
• If a PW800W is connected, the CL series will operate
correctly whether its own internal power supply and the
PW800W are both turned on, or just one of them is turned
on.
• If both power supplies are turned on, and an abnormality
is detected in one of the power supplies, the CL series will
automatically switch to the other power supply. If this
occurs, the touch screen will display a message to inform
you.
D
AC IN connector
Connect the supplied AC power cable here. First
connect the AC power cable to the CL unit, then insert
the power cable plug into an AC power outlet.
The supplied AC power cable features a special
latching mechanism (V-LOCK) to prevent the power
cable from being disconnected accidentally.
Connect the power cable by inserting the cable plug
fully until it is locked.
Caution
Be sure to turn the power off before connecting or
disconnecting the power cable.
To disconnect the power
cable, press the latch button
on the plug.
E
(Power Switch)
This switch turns power on or off. When the power
switch is set to
, the power to the unit is on. When
the power switch is set to
off.
Caution
• Rapidly turning the unit on and off in succession can cause
it to malfunction. After turning the unit off, wait for at least 6
seconds before turning it on again.
• Even when the power switch is turned off, a small amount
of current is flowing through the unit. If you plan not to use
the unit for a long period of time, remove the power cable
from the AC outlet.
F
Grounding screw
The supplied AC power cable is a 3-wire type.
Therefore, if the AC outlet used is properly grounded,
the CL will be grounded as well. Also, grounding this
screw may effectively eliminate noise such as hum and
interference.
Rear Panel
, the power to the unit is