5.3.32 Tone Settings
RINGBACK_TONE_GAIN
Value Format
Description
Value Range
Default Value
RINGBACK_TONE_RPT
Value Format
Description
Value Range
Default Value
RINGBACK_TONE_TIMING
Value Format
Description
Value Range
Default Value
Web User Interface Reference
HOLD_ALARM_FRQ
Value Format
Description
Value Range
Default Value
288
Administrator Guide
INTEGER
Specifies the gain, in decibels, of the ringback tone.
-24–24 (dB)
0
INTEGER
Specifies whether the ringback tone is repeated.
0–1
–
0: No Repeat
–
1: Repeat
1
Comma-separated Integer
Specifies the pattern, in milliseconds, of ringback tones using up to 10
whole numbers (off 1, on 1, off 2, on 2...) separated by commas.
Note
•
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
0–16000 (0: Continuous)
Note
•
Avoid setting 1–50 for any of the values.
60,1000,3940