Description
Value Range
Default Value
BELL_CORE_PATTERN5_TIMING
Value Format
Description
Value Range
Default Value
KEY_PAD_TONE
Value Format
Description
Value Range
Default Value
5.3.33 Call Control Settings
DEFAULT_LINE_SELECT
Value Format
Description
Value Range
Default Value
Web User Interface Reference
Document Version 2015-12
Specifies the cadence, in milliseconds, of pattern ID 4, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2...) separated by
commas.
0–5000 (0: Continuous)
Note
•
Avoid setting 1–50 for any of the values.
300,200,1000,200,300,4000
Comma-separated Integer
Specifies the cadence, in milliseconds, of pattern ID 5, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2...) separated by
commas.
0–5000 (0: Continuous)
Note
•
Avoid setting 1–50 for any of the values.
500
INTEGER
Specifies whether a tone is heard in response to key presses.
•
0: Off
•
1: On
1
INTEGER
Specifies the line used to make an outgoing call when no line is
specified in the dialing operation.
•
1: Line1
•
2: Line2
1
Default Line for Outgoing (Page 137)
5.3.33 Call Control Settings
Administrator Guide
291