Fault Codes - Rinnai FC510N User Manual

Fan convector heaters
Table of Contents

Advertisement

Fault Codes

An error code will flash on the unit's display when a fault occurs. Refer to the list of error codes below for details on your unit's
fault code. All troubleshooting and repairs should be made by a licensed contractor.
ERROR
00
03
11
ODS #1
12
ODS #1
ODS #2
Burner ODS #1 & Pilot ODS #2
13
ODS #1
(No flame inside burner assembly)
14
16
18
15
FAULT
Power Failure
Tilt Switch Activated
Missed Ignition
Burner Sensor
Pilot Sensor
Flame Failure
Overheat - Burner ODS #1
No Ignition
Overheat Sensor
Thermo fuse
Room Overheat
Thermocouple #1
- Press ON/Off button and allow unit to cycle on.
- Return unit to the upright position. Restart heater using the "ON" power button.
- Verify the gas supply is turned on to the appliance, gas meter, or tank
- Ensure gas type and inlet gas pressures are correct
- Bleed all air from gas lines
- Ensure gas line, meter, and / or regulator is sized properly
- Ensure appliance is properly grounded
- Verify ODS #1 and ODS #2 are producing the proper milli-voltage when unit fires.
- Inspect all wiring harnesses /connectors for loose, damage or broken connections .
- Replace defective ODS sensor
- ODS #1 left hand side of burner has sensed an over heat condition. Check filter
for blockage first. Then check fan for bad bearing, improper operation or hertz.
- Replace ODS #1 Sensor
- Verify air filter is in place and not clogged.
- Verify proper clearances around the appliance for air flow. Remove any obstructions.
- Check gas type of unit and ensure it matches gas type being used
- Verify low and high fire manifold gas pressures are properly set.
- Ensure DIP switches are set to the proper position on the PC board
- Check burner chamber for signs of heat stress, cracks and/or separations
- Check burner assembly for damage.
- Measure resistance of safety circuit
Verify unit was sized properly for space being heated.
Check for restrictions in air flow around unit.
Check thermocouple wiring for damage, loose or broken wires.
Measure resistance of thermocouple
Replace thermocouple
REMEDY

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fc510pFc824nFc824p

Table of Contents