AVFLST Vent Free Fireplace
Intermittent/Standing Pilot Setup (Default intermit-
tent)
1. Holding the ON button on the Command Center while
turning on the master switch will toggle between stand-
ing pilot and intermittent pilot.
2. After the above operation, one beep (for standing pi-
lot) or two beeps (for intermittent pilot) will be given as
confirmation.
Six-hour Safety Shutdown Option (Default ON)
1. The system comes preset from the factory with a six (6)
hour shutdown from its last command of operation.
This is done to prevent the fireplace from continuing to
operate if unattended. You may disable this feature if
you wish.
NOTE: By disabling this feature, your fireplace may con-
tinue to operate unattended.
2. When the master switch is in the ON position ("-"),
pressing the ON button and the OFF button on the
Command Center simultaneously will toggle between
enabling and disabling the six-hour shutdown option.
3. After the above operation, one beep (for enabling the
six-hour shutdown option) or two beeps (for disabling
the six-hour shutdown option) will be given as confirma-
tion.
Remote Transmitter Learn Function (Default OFF)
1. The RF receiver button located on the Control Board
must be in the on position before the learn function can
begin. Use paper clip to depress button. One beep for
RF receiver ON or two beeps for RF receiver OFF will
be given as confirmation. Refer to Figure 17 for location.
SIGNATURE COMMAND
FUNCTION
Intermittent/Standing Pilot
Setup
Standing Pilot
Temperature Shutoff
RF Remote Receiver
ON/OFF
Learn Remote
Transmitter
6-Hour Safety
Shutdown Setup
20308636
SYSTEM FUNCTION SETTINGS
®
Hold the ON é button while turning the master switch
(It will beep once for standing pilot, twice for intermittent pilot.)
Hold the ON é button for 3 seconds (when the master switch on
the main burner is off.)
Push the RF receiver ON/OFF button on the control board.
(It will beep once for On and twice for OFF.)
Hold the OFF ê button while turning on the master switch
(Listen for two beeps, then press any button on the remote.)
Press the ON é button and OFF ê button simultaneously
(It will beep once for ON, twice for OFF.)
SIGNATURE COMMAND
2. After the RF receiver is on, holding the OFF button on
the Command Center while turning on the master switch
will activate the learn function for the transmitter.
3. After the above operation, two beeps will be given and
the green LED on the Command Center will flash for
10 seconds.
4. During the 10 seconds, press the OFF button on a
transmitter to learn. Another two beeps will be given
to confirm a successful learning. Refer to transmitter
instructions for remote operations.
Shutting Off the Standing Pilot (Temporary Shut Off)
To shut off the standing pilot for service or summer shut
down, press and hold the ON button on the Command
Center for 3 seconds when the master switch is in the ON
position ("-") and the main burner is off.
Note: Pilot will resume the next time system is turned
on.
Key Combinations for System Settings
NOTE: When On/Off wall switch is used, it must be in the
On position to perform all system setups.
OPERATION
SYSTEM OPERATION
®
DEFAULT SETTING
INTERMITTENT
PILOT
RF OFF
ON
19