GETTING STARTED

Check to verify that all listed parts have been received.
You should have the following:
• One (1) Unvented gas heater
• Two (2) Anchoring screws
• One (1)Installation/operating instructions
• Two (2) 5" noncombustible board
• Two (2) 2" x 32" deflector glass
• Two (2) Bags fireglass
• One (1) 100 watt bulb
• One (1) TSFSC remote control
Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance. Do not
attempt to install any part of the appliance unless you
have all parts in good condition.

WHAT YOU WILL NEED FOR INSTALLATION

You must have the following items available before pro-
ceeding with installation:
• External regulator (for propane/LPG only)
• Manual shutoff valve
• Piping which complies with local codes
• Sediment trap
• Phillips head screwdriver
• Tee joint.
• Pipe sealant approved for use with propane/LPG
(Resistant to sulfur compounds)
• Pipe wrench
Do not install the heater:
Where curtains, furniture, clothing, or
other flammable objects are less than 36"
from the front of the heater.
In high traffic areas.
In windy or drafty areas.
20308636
WARNING!

PRE-INSTALLATION INFORMATION

PLANNING THE INSTALLATION

In planning the installation for the fireplace it is necessary
to determine where the unit is to be installed and whether
optional accessories are desired. Gas supply piping should
also be planned. The following steps represent the normal
sequence of installation. Each installation is unique, how-
ever, and might require a different sequence.
1. Position fireplace in desired location. Refer to the
Fireplace and Framing Dimensions (page 6, Figures 2
and 3,) Fireplace Location (page 8, Figure 5) and
Clearances and Height Requirements (page 9, Figures
6 and 7.)
NOTE: Be sure all cardboard packing material has been
removed from under the unit.
2. Install following the instructions found in this manual.
3. Field wire main power supply to junction box. Refer to
the Electrical Installation section (page 13). (Electrical
connections should only be performed by an experi-
enced, licensed certified service person).
4. Plumb gas line. Refer to the Connect the Gas (page
11, Figure 10) section found in this manual. (Gas
connections should only be performed by an experi-
enced, licensed/certified service person).
5. Complete finish wall material and/or surround.
ADEQUATE COMBUSTION AND
VENTILATION AIR
This heater shall not be installed in a confined space or
unusually tight construction unless provisions are provided
for adequate combustion and ventilation air.
The National Fuel Gas Code, (ANSI Z223.1/NFPA54),
defines a confined space as a space whose volume is less
than 50 cubic feet per 1,000 BTU per hour (4.8m
of the aggregate input rating of all appliances installed in
that space, and an unconfined space as a space whose
volume is not less than 50 cubic feet per 1,000 BTU per
hour (4.8 m
per kw) of the aggregate input rating of all
3
appliances installed in that space. Rooms communicating
directly with the space in which the appliances are installed,
through openings not furnished with doors, are considered
a part of a confined space.
Unusually tight construction is defined as construction
where:
a. Walls and ceilings exposed to the outside atmosphere
have a continuous water vapor retarder with a rating of
1 perm (6 x 10
kg per pa/sec-m
11
gasketed or sealed, and
b. Weather stripping has been added on openable win-
dows and doors, and
per kw)
3
) or less with openings
2
7