ELECTRICAL INSTALLATION
SIGNATURE COMMAND
Thermocouple
Module
CONTROL
MODULE
NOTE: Wall switch wires must
be connected together if a wall
switch is not being used.
Figure 13. Signature Command
14

WIRING DIAGRAM

®
Thermocouple
Top Lamp
TO JUNCTION BOX
100w
IN FIREPLACE
Hearth Light
WHITE
BLACK
Opt. Blower
WHITE
WHITE
BLACK
BLACK
Orange
Wiring Diagram
®
A/C MODULE
GREEN
Control Board
Plug-in Connector
Control Board to Command Center
Plug-in Connector
Stepper Motor to
Control Board
Ground
DC Power/Green
Plug-in Connector
Control Board to
Solenoid
Gas In
Valve
AVFLST Vent Free Fireplace
Pilot
RF Receiver
ON/OFF Button
Black / Thermopile
Red / Thermopile
Sensor
Ignitor / Sparker
Red
LED
OFF/LO
ON/HI
Master Switch
Command Center
Gas Out
Pilot Gas Tubing
Optional
Wall Switch
FP3010