Oki OKIPAGE 8p Maintenance Manual page 86

Led page printer
Hide thumbs Also See for OKIPAGE 8p:
Table of Contents

Advertisement

4
Heat assy error
• Turn the power supply off, then on again.
• Does the Halogen lamp of the heat assy go on?
• No
• Yes Replace the heat assy, Halogen lamp, or thermostat.
• No
• Yes
Are the CN2 connectors of the power supply unit and main control board connected
correctly?
• No
• Yes
Replace the main control board.
Is the Halogen lamp or thermostat disconnected?
Replace the power supply unit.
Connect the CN2 connectors correctly.