Location Requirements; Electrical Requirements - Hisense AP-10CR1SEPS Use And Installation Instructions

Table of Contents

Advertisement

Available languages

Available languages

NOTES:
■ The flexible exhaust hose allows placement of the air
conditioner between 23⁵⁄₈" and 64 " (60 cm and 163 cm)
from window or door
■ Confirm you are using the correct size air conditioner for the
space to be cooled, per sizing recommendations, below:
Area to be cooled
Square Footage
Up to a 10 x 20 Room
200
300
Up to a 15 x 20 Room
Up to a 20 x 20 Room
400
500
Up to a 20 x 25 Room
:
Adjust BTUs to room use and location:
NOTE
■Shaded room reduce by 10%
■Sunny room increace by 10%
■For occupancy over two people add 600 BTUs per
person
■Kitchen use add 4,000 BTUs
Vertical Slide Widow
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.

Location Requirements

¹⁄₈
Capacity needed
(BTUs)
"
"
8,000
"
"
10,000
"
"
12,000
"
"
14,000
23⁵⁄₈" - 64¹⁄₈"
(60 cm - 163 cm)

Electrical Requirements

Horizontal Slide Window
NOTES:
■ To ensure proper ventilation, keep the required distance from
the return air outlet to the wall or other obstacles at least
23⁵⁄₈" (60 cm).
■ Do not block the air outlet.
■ Provide easy access to the grounded 3 prong outlet.
■ The portable air conditioner should be dedicated to a 115V, 60
Hz, 15-amp fuse grounded 3 prong outlet.
■ The use of a time-delay fuse or time-delay circuit breaker is
required.
■ All wiring must comply with local and the national electrical
codes and be installed by a qualified electrician. If you have
any questions, contact a qualified electrician.
4
23⁵⁄₈" - 64¹⁄₈"
(60 cm - 163 cm)