Maintenance; General And Annual Cleaning; Accent Lamp Bulb Replacement; Battery Replacement - Jøtul GI 535 DV IPI New Harbor Installation And Operation Instructions Manual

Direct vent fireplace insert
Hide thumbs Also See for Jøtul GI 535 DV IPI New Harbor:
Table of Contents

Advertisement

139775_R03_GI 535 DV IPI June 2016

9.0 Maintenance

CAUTION:
THE IGNITION SYSTEM OF THIS APPLIANCE CARRIES
LIVE VOLTAGE. ALWAYS TURN OFF THE GAS SUPPLY
TO THE INSERT AND DISCONNECT THE POWER
SOURCE BEFORE ANY SERVICE WORK IS PERFORMED,
INCLUDING BATTERY REPLACEMENT.
With proper care and maintenance, your appliance will
provide you with years of enjoyment. If you experience
any problem with your fireplace insert, contact your Jøtul
Authorized Dealer for assistance.
KEEP THIS MANUAL FOR REFERENCE AND MAKE IT
AVAILABLE TO ANYONE USING OR SERVICING THE INSERT.
This appliance and venting system should be
inspected before use and at least annually by a qualified
service technician
9.1 General Cleaning
• Vacuum the controls area under the firebox at
least monthly or more frequently if pet hair is in
the environment. Always keep the appliance area
clear and free from combustible materials, gasoline
and other flammable liquids. ALWAYS BE SURE THE
BURNER AND FIREBOX ARE COLD before using a
vacuum cleaner.
• The firebox should be vacuumed annually. Inspect
the pilot assembly for corrosion and have any
damaged components replaced by a qualified service
technician. Remove any debris from burner ports,
particularly the pilot carry-over ports. See fig. 7.22,
page 22. Use a brush attachment to vacuum the log
set.
Gasket Inspection
• Inspect the glass gasket annually. Examine the
gasket for signs of deterioration or stiffness and
confirm that the gasket maintains a positive seal.
This is important to prevent combustion gases
escaping into the room. Replace the gasket if
necessary. Refer to the replacement parts list on
page 38.
32
9.2 Accent Lamp Replacement
1. Remove the cast iron overlay assembly, backer plate,
and glass frame.,
2. Remove the bulb receptacle (two screws). See fig. 10.7,
pg. 38. Replace with 222943 130V, 50W light bulb.
3. Handle the new bulb with gloves. Skin oils will cause
the bulb to fail prematurely. If you touch the bulb with
your bare skin, wipe it clean with a soft cloth.
4, Replace components previously removed.

9.3 Battery Replacement

A Low Battery condition is indicated by an audible
"double beep" signal from when a command is
transmitted.
1. Disconnect electrical power from the appliance.
2. Remove the cast iron overlay.
3. The battery box located in the right side control
compartment. Depress the cover plate tabs to open
the box. Install four new AA batteries noting the
polarity indicated on the front of the box.
CAUTION:
ALWAYS DISCONNECT ELECTRICAL POWER WHEN
SERVICING THIS APPLIANCE.
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING THE CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND DANGEROUS
OPERATION. ALWAYS VERIFY PROPER OPERATION
AFTER SERVICING THE APPLIANCE.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gi 535 dv ipi new harbor

Table of Contents