8.3.2 Remote Control Functions
Pilot Mode Control
The IPI/CPI functionality will be fully controlled by
the remote transmitter. See Pilot Mode, page 30.
REMOTE - Set the burner switch to REMOTE to
enable remote control burner operation.
OFF - Turns off burner functionality. Switch to OFF
when the fireplace will not be used for an extended
period of time.
ON - The burner will immediately light, regardless
of the Remote transmitter setting.
Remote Transmitter
The Transmitter features a simple button layout and
informative display screen. See figs. 8.6-8.7.
LCD DISPLAY - graphically indicates temperature
settings and status of the Thermostat, Burner, Fan, and
Accent Lamp.
ON / OFF Key - controls Burner, Fan, and Lamp functions.
THERMOSTAT Key - Used to set either Manual or
Thermostatic Control and index through thermostatic
functions.
UP / DOWN Arrow Key - Selects thermostat
temperature range, fan speed, and flame height.
MODE Key - used to select the component to be
controlled: CPI/IPI, Front Burner, Blowers, and Accent
Lamp.
The included Wall Mount Bracket can be used for
convenient Transmitter storage away from curious
children.
Transmission
Thermostat
ON / OFF / SMART
Set Point
Temperature Level State
Burner
Modulation
Fan Modulation
Figure 8.7. Remote transmitter display data.
°F
°C
OFF
ON
SMART
MAX
MAX
Lamp Modulation
IFC / Transmitter Mode Synchronization
1. Install three fresh AAA batteries into the Transmitter.
2. Set the fireplace Burner Switch to REMOTE.
3. Press the black initialization button (PRG) at the
lower right of the battery box faceplate (fig. 8.4, page
27). The board will "beep" three times signalling a
10-second synchronization time limit.
4. Within the 10-second time frame, push the ON button
on the Transmitter. The IFC will "beep" three times to
indicate that it has acknowledged the transmitter
command and sets to the particular code of that
transmitter.
5. After initialization, the burner switch should be left in
the REMOTE position for normal operation.
For Manual Only functionality, hold the
battery box initialization button (PRG) down
until it "beeps" three or four times. Within 10
seconds, push the button again until it signals
acknowledgement that the Remote function is off.
NOTE: In Manual functionality, there is no control
over the blower, lamp, or pilot modes. The pilot
defaults to CPI mode.
Figure 8.6.
Remote transmitter
function keys.
Child Safety Lock-out
Low Battery Alarm
Room
Temperature
CPI Mode
AUX
(Not Applicable)
Split Valve
139775_R03 GI 535 DV IPI June 2016
Blue LCD Screen
ON/OFF Key
THERMOSTAT Key
UP/DOWN Key
MODE Key
29