Eliminating Minor Faults Yourself - Bosch KGF39P90 Operating Instructions Manual

Table of Contents

Advertisement

Eliminating minor faults yourself

Before you call customer service:
Please check whether you can eliminate the fault yourself based on the following
information.
Customer service will charge you for advice, even if the appliance is still under
guarantee!
Fault
Temperature
differs greatly
from the set value.
Displays do not
illuminate.
Warning signal
sounds, alarm"
display lights up.
Downloaded from Fridge-Manual.com Manuals
Possible cause
Power failure; the fuse has been
switched off; the mains plug has
not been inserted properly.
Fault the freezer compartment is
too warm!
S Ventilation openings have been
covered.
S Freezer compartment door is open.
S Too much food was placed in the
freezer compartment at once.
When the fault has been eliminated,
the indicator light goes out shortly
afterwards.
Remedial action
In some cases it is adequate to switch
off the appliance for 5 minutes.
If the temperature is too high wait
a few hours and check whether the
temperature has approached the set
value.
If the temperature is too low check
the temperature again the next day.
Check whether the power is on, the fuse
must be switched on.
To switch off the warning signal,
press the Alarm button, Fig. 2/2.
Ensure that there is adequate ventilation.
Close the door.
Do not exceed max. freezing capacity.
en
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kgf series

Table of Contents