Gas Pressure Fryer
To refill the pot automatically, use the steps below:
Place the FILL handle to the THRU POT position.
Position the FILTER/OFF/FRY switch to FILTER and shortening will automatically pump into the
pot.
Let the filter continue to pump the shortening until the fill mark in the fryer pot is reached or until
air starts bubbling through the shortening.
As soon as air is seen in the shortening, first place the FILL handle to the THRU HOSE position
then position the FILTER/OFF/FRY switch to OFF to prevent shortening degradation and prevent
the filter pump and lines from filling up with shortening.
Add new shortening if the fill mark has not been reached.
To refill the pot through the rinse hose, use the steps below:
Make certain that the rinse hose is connected to rinse hose connector.
Holding the hose by the handle, place hose nozzle inside the pot.
Position the FILL lever in the THRU HOSE position.
Position the FILTER/OFF/FRY switch to FILTER and shortening will automatically pump into the
pot.
Let the filter continue to pump the shortening until the fill mark in the fryer pot is reached or until
air starts bubbling through the shortening.
As soon as air is seen in the shortening, position the FILTER/OFF/FRY switch to OFF to prevent
shortening degradation.
Add new shortening if the fill mark has not been reached.
Boil-Out Procedure
Boil-outs remove microscopic particles of carbon that build up on the walls of the fryer pot. To avoid eventual
carbon build-up, off flavors, and shortening breakdown, boil-outs should be done once a week on each fryer
following these procedures.
1. Position the FILTER/OFF/FRY switch to OFF.
2. Drain the clean shortening into an adequate storage container. (Allow the shortening to cool to room
temperature before attempting storage.)
3. CLOSE the drain and fill the fryer pot with HOT water to the shortening level fill mark. Do not overfill by
allowing the water level higher than the fill mark.
4. Add ½ cup (4 ounces) of BKI cleaner.
5. Wash down the inside of the pot with the pot brush to loosen the sediment.
Always wear appropriate personal protection equipment during the boil-out
process to guard against possible injury from hot cleaning solution.