BKI BLG Operation Manual page 16

Extra-large gas auto-lift fryer
Table of Contents

Advertisement

Gas Pressure Fryer
Item
Description
1
Computer
2
Momentary Switch
3
Rocker Switch
4
Thermostat Knob
5
Thermostat Light
6
Digital Timer
LED indicator
TIME SELECT (2
arrow buttons)
START/STOP button
ALARM button
Function
Used to program the cooking computer and activate the programs
BASKET UP – Momentarily pushing the switch to this position causes the
lift mechanism to rise. This is enabled only when the FILTER/OFF/FRY
switch is in the FRY position.
BASKET DOWN – Momentarily pushing the switch to this position causes
the lift mechanism to lower. This is enabled only when the
FILTER/OFF/FRY switch is in the FRY position.
FILTER – When placed in this position, power is applied to the motor and
shortening is pumped into the pot directly or through the fill hose.
OFF – When placed in this position, power is removed from the pump
motor, heating elements and lift mechanism.
FRY – When placed in this position, power is supplied to the thermostat (or
computer), heating elements and lift mechanism.
Used to set the temperature of the shortening.
Illuminates to indicate that the elements have power applied to them.
The digital timer consists of an LED, display, beeper and 8 buttons
described below:
Prior to the start of a timing cycle the LED will be OFF. When running a
timing cycle the LED will flash. At the end of a timing cycle the LED will
turn ON steady. When idle the LED is off.
Two arrow buttons on the front panel are used to set the time. Hold the UP
ARROW button down to increase the time. The longer the button is held
down, the faster the rate at which the time will increase. The DOWN
ARROW button is used in the same manner as the UP ARROW button
except it will cause the time to decrease. The time is increased or
decreased in 30-second increments.
Starting the Timer - Pressing this button while the timer is not active will
cause the timer to begin counting down the time on the display.
Stopping the Timer - Pressing this button while the timer is active will
stop the timer from counting down and display the remaining time. Time
cannot be changed with the TIME SELECT buttons at this point. If this
button is pressed again the timer will continue counting down from the
point it was stopped.
Resetting the Timer - Pressing and holding this button for longer than two
(2) seconds will reset the timer and the display will return to the original
starting time. At this point, time can be changed using the TIME SELECT
buttons or the preset buttons.
Canceling The STIR OIL Function - Pressing this button cancels the
STIR OIL function while it is active.
This button allows the user to set an elapsed time at which the internal
alarm will sound during a cycle. The time is set by pressing and holding
the ALARM button while using the UP and DOWN arrows to change the
time. The controller will limit the alarm time to be less than the currently
programmed interval cycle time. The default alarm time is 0:00 which
disables it. The ALARM time is saved on power down in the same manner
as the last interval time. When a time cycle is running and the alarm time
has elapsed the internal alarm will sound for 10 seconds. For example, a
cycle time 10:00 and alarm time of 2:00 would cause the alarm to sound
for 10 seconds once the controller has counted down from 10:00 to 8:00.
This button is also used to cancel the STIR OIL function.
13
Operation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Blg-fBlg-fc

Table of Contents