Page 1
Gas Pressure Fryer MODELS LGF, LGF-F, & LGF-FC Service Manual Serial Numbers 137733 and higher...
Page 2
LIMITED ONE YEAR WARRANTY BKI (The "Company") warrants to the original purchaser that at time of shipment from the Company factory, this equipment will be free from defect in materials and workmanship. Written notice of a claim under this warranty must be received by the Company within ONE YEAR from the date of installation, but no longer than ONE YEAR AND THREE MONTHS from date of shipment from the factory.
Gas Pressure Fryer The LGF Pressure Fryer is compact, attractive and functional in design. It is constructed of a stainless steel fryer pot for cleaning ease. Exclusive BKI patented features and safety devices offer flexibility, efficiency and reliability plus PERFECTION IN PRESSURE FRYING! The BKI name and trademark on this unit assures you of the finest in design and engineering -- that it has been built with care and dedication -- using the best materials available.
Gas Pressure Fryer Specific Precautions Lids for LGF Pressure Fryers manufactured prior to May 27, 1980 (or units with serial numbers lower than 3613) could be manually opened while under pressure resulting in serious injury or death. If you have one of these units, please contact the BKI Technical Services Department toll-free at 1-800-927-6887 for urgent update information.
Make sure to keep the area around your fryer clear of any obstacles. Serious injury can occur if you trip or fall near the fryer. You could be burned by hot shortening that splashes out of the fryer or by falling against the hot metal of the fryer.
Page 7
Make sure to keep the floor around your fryer clean of shortening and other liquids. Serious injury can occur if you slip near your fryer. You could be burned by hot shortening that splashes out of the fryer or by falling against the hot metal of the fryer.
Page 8
Always wear your insulated mitts when handling the fryer basket or touch any hot metal surfaces. You received a pair of insulated mitts with your fryer. If you lose or damage your mitts, you can buy new ones at your local restaurant equipment supply store or from your local BKI Distributor.
Page 9
Keep Away From The Vent Hot steam escapes from the vent continuously when you are using your fryer. You could be burned if you get too close to the vent. Keep this manual with the Equipment This manual is an important part of your equipment. Always keep it near for easy access.
Page 10
• Make certain that you have thoroughly trained your employees about operating the equipment safely. • Make certain the equipment is in proper working condition. If you make unauthorized modifications to the equipment, you will reduce the function and safety of the equipment. Do Not Smoke Near The Fryer. Introduction...
Gas Pressure Fryer Installation Installation For installation information, refer to Gas Pressure Fryer, MODELS LGF, LGF-F, & LGF-FC, Installation and Operation Manual LI0101.
Gas Pressure Fryer Operation Operation Controls and Indicators Refer to the figure and table below for an explanation of the fryer’s controls and indicators.
Page 15
Gas Pressure Fryer Item Description Pressure Gauge Spin Handle Pop Safety Valve lever Computer Rocker Switch Thermostat Knob Thermostat Light Digital Timer LED indicator TIME SELECT (2 arrow buttons) START/STOP button ALARM button Function Indicates the pressure inside the pot.
Page 16
Gas Pressure Fryer Item Description A, B, C, D preset buttons Beeper Display High Limit Reset Switch Gas Control Valve Switch Drain Lever Fill Lever Pump Motor Reset Switch Rinse Hose Connector Function These buttons are used to save and recall preset cycle and alarm times, saving operator time and minimizing error when changing interval cycle times and alarm times.
6. DO NOT HOLD SHORTENING AT HIGH TEMPERATURE when the fryer is not in use. If you expect an elapsed time of one hour or more between cooking, close the lid and press the “0” button on the LGF-FC model. On Models LGF and LGF-F, set the thermostat to 150º F.
Gas Pressure Fryer The LGF/LGF-F fryer has a maximum temperature setting of 375º F (190º C). Do not use oil/shortening with a flashpoint less than 554º F (290º C) Use only high-quality shortening that has low moisture content, a high smoke point and no additives.
Page 19
14. Remember to filter the shortening at least every third frying cycle load. Refer to the procedure in this manual. Also filter the shortening and clean the fryer at the end of each day. If you do not plan to use the fryer for an hour or more, turn the thermostat down to 150°...
Gas Pressure Fryer Operation LGF-FC Operation System Programming Use the following figure and table to set options that apply to each product programs. Figure 1. System Programming Sequence...
Page 21
Gas Pressure Fryer STEP ACTION Press the FILTER/OFF/FRY switch to FRY. Press PROG on the keypad. Input 1712 and ENTER. Press ENTER. Press TOGGLE/CLEAR until the desired option is displayed. Press ENTER. Press TOGGLE/CLEAR until the desired option is displayed.
Gas Pressure Fryer Operation Product Programming Use the following figure and table to set a maximum of eight product programs. The product programs must be set before cooking can begin. Figure 2. Product Programming Sequence...
Page 23
XXX refers to the cooking temperature you input. This command enables you to select whether or not time is allowed for the fryer to recover from temperature loss while cooking during this stage. The FLEX TIME option will allow the fryer to recover from temperature loss.
Page 24
Gas Pressure Fryer STEP ACTION Repeat steps 5-12 when programming stages 2, 3, 4 and 5 for Electric and Gas appliance types. Repeat steps 5-10 when programming stages 2, 3, 4 and 5 for an ALF appliance type. Press ENTER.
Do not use any shortening other than what is specified in this manual and do not overfill the fryer pot. The LGF-FC fryer has a maximum temperature setting of 390º F (200º C). Do not use oil/shortening with a flashpoint less than 554º F (290º C) Use only high-quality shortening that has low moisture content, a high smoke point and no additives.
Page 26
Failure to use the insulated mitts will result in injury. Always use the insulated mitts when handling the hot fry basket. 13. Connect the basket handle then lift the basket and hang it on the front of the fryer pot to drain. 14. Empty the basket.
Fried Onion Rings 1. Take frozen onion rings from freezer or bread fresh onion rings with Imperial breading. 2. Place onion rings into fryer basket. 3. Close cover to begin pressure frying. 4. Cook for 4 minutes at 350°F for frozen product.
Page 28
4. Cook for 20 to 25 minutes at 300°F. Pork Chops 1. Bread each chop with Imperial breading. 2. Place pork chops into fryer basket. 3. Close cover to begin pressure frying. 4. Cook for 8 to 10 minutes at 325°F depending on size.
Gas Pressure Fryer Operation After Gas or Power Outage The fryer may shut off automatically if the gas supply is interrupted or the power goes out. If either of these conditions occur you should perform the following procedure: For your safety, if the gas supply stops, or, if the power goes out, make sure to wait for at least five minutes before restarting your fryer.
Gas Pressure Fryer Maintenance Maintenance For maintenance information, refer to Gas Pressure Fryer, MODELS LGF, LGF-F, & LGF-FC, Installation and Operation Manual LI0101.
Page 32
Gas Pressure Fryer Replacement Parts Figure 3. Lid/Arm Assembly, AN3211350S (Sheet 1 of 4)
Page 33
Gas Pressure Fryer Replacement Parts Figure 3. Lid/Arm Assembly, AN3211350S (Sheet 2 of 4)
Page 34
Gas Pressure Fryer Replacement Parts Figure 3. Lid/Arm Assembly, AN3211350S (Sheet 3 of 4)
Page 35
Gas Pressure Fryer Replacement Parts Figure 3. Lid/Arm Assembly, AN3211350S (Sheet 4 of 4)
Page 36
SPRING, HOOK LGF LPF FKM SCREW, 1/4-20 X 1/2 FLAT HD SCREW, 1/4-20 X 1/2 PHIL RD HD BUSHING, BRONZE 1" HANDLE SIDE FOR H0155 FKM LPF LGF WASHER, 5/16 LOCK ZINC PLTD WASHER, 1/4 INT LOCK PLUG, HOLE 3/8" SHORT PRONG...
Page 37
COVER, DEAD WEIGHT VALVE FKM WEIGHT, VALVE FKM 12# ORIFICE, SS NIPPLE, 1/2 X 3 3/4 SS SCH 80 BODY, DEAD WEIGHT VALVE LGF SS NIPPLE, 1/2 X 2 SS 304 NIPPLE, 1/4 X 1 1/2 SS 304 ELL, STREET 1/4 90 DEG CP...
Page 38
Gas Pressure Fryer Replacement Parts Figure 5. Drain/Motor/Piping Assembly...
Page 39
DRAIN VALVE BRACKET, FRYERS NUT, 6-32 S/S 18-8 NYLON COVER, MICROSWITCH SWITCH, MICRO BZ-2RW822-A2 HANDLE PLATE WELD DECAL, DRAIN SUPPORT PLATE LGF SCREW, 6-32 X 1-3/4 SLTD RD HD HANDLE, DRAIN VALVE COVER, DRAIN HANDLE RED HANDLE, FILL VALVE COVER, FILL HANDLE BLACK...
Page 40
Gas Pressure Fryer Replacement Parts Figure 6. Burner Tray Assembly...
Page 41
INSULATION, BOARD 7/16 BURNER TRAY FRONT W/SLOT PILOT BRKT, HOT SURFACE IGNITION S/S TUBING 304 1/4 DIA CORRUG.18" MANIFOLD ASSY, LGF LP NO DWG BURNER ORIFICE, LP O0005 MANIFOLD, GAS SUPPLY BURNER TRAY, REAR WELD LGF NATURAL GAS BURNER TRAY ASSEMBLY...
Page 42
Gas Pressure Fryer Replacement Parts Figure 7. Control/Insulation Panel LGF & LGF-F...
Gas Pressure Fryer Refer to the table below to find the wiring diagram associated with your unit. Wiring Diagram LGF-F 120V/60HZ/1 Phase LGF-FC 120V/60HZ/1 Phase LGF-FC 220V/50HZ/1 Phase LGF-FC 220V/60HZ/1 Phase LGF-FC 240V/50HZ/1 Phase Wiring Diagrams Diagram # SB322901 LGFE1034...