Prepare Boiler Location - Freestyle 80 Manual

Wall mount gas-fired condensing boilers
Hide thumbs Also See for 80:
Table of Contents

Advertisement

®
W
FreeStyle
ALL

2 Prepare boiler location

Codes & checklist
Installations must comply with:
Local, state, provincial, and national codes, laws, regulations
and ordinances.
National Electrical Code.
The
FreeStyle®
latest edition.
Flooring
1. The boiler must not be installed on carpeting.
tion is used. Fire can result, causing severe personal
injury, death or substantial property damage.
1.
See page 9
2.
3.
System water piping
Venting connections
Gas supply piping
Electrical power
Condensate drain
4. Check area around boiler. Remove any combustible materials,
gasoline and other flammable liquids.
tible materials, gasoline and other flammable liquids
and vapors can result in severe personal injury, death
or substantial property damage.
5. The
FreeStyle®
boiler must be installed so that gas control
water or rain during operation or service.
6.
system problems, such as:
Sediment or corrosion in system piping — clean and flush
piping BEFORE connecting the new boiler. See page 67.
System leaks causing oxygen corrosion or heat exchanger
Incorrectly-sized expansion tank.
Residential garage installation
1.
dential garage:
the floor. This complies with the National Fuel Gas Code,
6
M
-
OUNT GAS
FIRED WATER BOILER
only.
Boiler Manual
Locate or protect the boiler so it cannot be damaged by
a moving vehicle.
Ensure that the installation complies with all applicable
codes.
Provide air openings to room
®
FreeStyle
boiler alone in boiler room
met
1.
clearances around FreeStyle® boiler are at least equal to the
SERVICE clearances shown in Figure 2, page 7.
2. For spaces that DO NOT supply the minimum service clear-
ances, provide two openings as shown in Figure 2, page 7.
-
®
FreeStyle
1. Follow the sizing requirements shown in Figure 23, page 22.
The space must be provided with combustion/
appliances located in the same space as the
FreeStyle ® boiler.
room as other appliances.
Failure to comply with the above warnings
-
could result in severe personal injury, death or
substantial property damage.
Vent and air piping
1. The FreeStyle® boiler requires a special vent system, designed
the vent). See instructions beginning on page 17.
2.
air intake adapter. The resultant installation is categorized as
tion air contamination on page 8 when considering vent/air
termination.
3. Vent and air must terminate near one another unless otherwise
specified in this manual. Vent and air piping may be routed
piping methods covered in this manual. Do not attempt to
install the FreeStyle® boiler using any other means.
-
4. Be sure to locate the boiler such that the vent and air piping
can be routed through the building and properly terminated.
The vent/air piping lengths, routing and termination method
must all comply with the methods and limits in instructions
beginning on page 17.
FreeStyle®
Part number 550-142-850/0716
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

155120

Table of Contents