Quick Start Guide - Using Default Settings - Freestyle 80 Manual

Wall mount gas-fired condensing boilers
Hide thumbs Also See for 80:
Table of Contents

Advertisement

®
W
FreeStyle
ALL
Quick Start Guide
1
Figure 1
After you have completed the installation of the
the instructions provided in the manual, pages 5-71 insure the following first before you proceed:
All gas lines are connected and tested for leaks, and if the boiler is to operate on LP fuel, and the unit has been
converted properly from Natural gas to Liquefied Petroleum (Propane) gas and set up as directed in the boiler
manual.
All water piping, heating (and domestic if a Combi boiler) is installed correctly and free of leaks with the proper
accessories; proper sized expansion tank, water feed valve adjusted, low water cut-off devices installed and tested,
all operation control exterior to the boiler installed such as thermostats, and zone control panels.
1
Push ECO / Comfort / Power button; to start boiler
NOTE: if A-16 error code is displayed (Central Heating Only boiler) when unit is powered up,
the outdoor sensor is not installed. Install outdoor sensor and push the reset button to reset
2
error code. A faulty outdoor sensor will give an "F-39" error code.
3
03 "shows on the display" (control software version)
4
FH "shows on the display" (Fan /inducer operating in purge mode of combustion chamber and venting for 5 minutes).
5
With no "call for heat" (current boiler water temperature will be shown in degrees F).
To Change "Central Heating water temperature set-point" (from 68 F to 194 degrees F) use the bottom set
6
of "+" or "–" keys to raise or lower the set point temperature.
To change "Domestic water temperature set-point" (Combi Boiler) ( from 104 F to 131 degrees F ) NOTE: In-
7
sure that operating temperature is a safe set-point temperature. Use the top set of "+" or "–" keys to raise or lower the set point.
Part number 550-142-850/0716
M
-
OUNT GAS
FIRED WATER BOILER
— using default settings
QUICK START GUIDE
FreeStyle
System start
Boiler Manual
®
Boiler (Combi or Central Heating only models) by
60-65
.
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

155120

Table of Contents