CASTER SySTEM ASSEMBLy
Not all units are equipped with the same caster system. Follow the instruc-
tions, which apply to your specific unit.
Without Caster feet
you will find four casters (figure 1) with your wet/dry vacuum. Assemble as follows:
1. With cord disconnected from receptacle and tank cover removed, turn tank upside down so
that bottom is facing up.
2. Insert casters into bottom of tank by placing stem
of caster into holes provided. Apply pressure and
twisting motion until casters snap into place
(figure 2).
3. Return tank to upright position.
With Caster feet
If your caster feet look like the ones pictured in Figure 3, follow these instructions.
you will find four caster feet (figure 3), four casters (figure 4), and four screws with your
wet/dry vacuum. Assemble as follows:
1. With cord disconnected from receptacle and tank cover removed, turn tank upside down
so that bottom is facing up.
2. Remove any webbing that attaches the caster feet to each other.
3. With front of tank inlet facing you, take caster feet marked with the letter A (figure 5) and
insert stem of caster foot into holes on left front and right rear of tank also marked with
letter A (figure 6). make sure caster feet are fully inserted into tank bottom and secure with
screws provided (figure 7).
4. Take caster feet marked with the letter B (figure 8) and insert stem of caster foot into
holes on right front and left rear of tank also marked with the letter B (figure 9). make
sure caster feet are fully inserted into tank bottom and secure with screws provided
(figure 10).
5. Insert casters into feet by placing stem of caster into holes provided. Apply pressure and
twisting motion until casters snap into place (figure 11).
6. Return tank to upright position.
3
4
7
8
B
B
B
If your caster feet look like the ones pictured in Figure 12, follow these instructions.
you will find four caster feet (figure 12), four casters (figure 13) and four screws with your
wet/dry vacuum. Assemble as follows:
1. With cord disconnected from receptacle and tank cover removed, turn tank upside down so
that bottom is facing up.
2. With front of tank facing you, take caster feet marked with the letter A (figure 14) and place
in slots on left front and right rear of tank also marked with the letter A (figure 15). Secure
with screws provided (figure 16).
3. Take caster feet marked with the letter B (figure 17) and place in slots on right front and
left rear of tank also marked with the letter B (figure 18). Secure with screws provided
(figure 19).
4. If flat washers are included in hardware package place flat washer over stem of caster before
installing casters into feet. NOTE: flat washers are not required with all units.
5. Insert casters into feet by placing stem of caster into holes provided. Apply pressure and
twisting motion until casters snap into place (figure 20). Return tank to upright position.
12
13
18
17
B
B
B
B
A
With Rear Caster Dolly/Tool Holder
you will find four casters (figure 21), two caster feet (figure 22), rear caster dolly/tool holder
(figure 23), and four screws with your wet/dry vacuum. Assemble as follows:
21
1. With cord disconnected from receptacle and tank cover removed, turn tank upside down so
that the bottom is facing up.
2. Take rear caster dolly and place into slots (on rear of tank, opposite of drain) and secure with
screws provided (figure 24).
3. If flat washers are included in hardware package place flat washer over stem of caster before
installing casters into feet. NOTE : flat washers are not required with all units.
1
5
6
A
A
9
10
11
B
A
B
B
A
B
14
15
16
16
A
A
A
A
A
A
19
20
A
B
B
22
23
4. Insert casters into bottom of rear caster dolly by placing stem of caster into holes provided.
Apply pressure and twisting motion until casters snap into place (figure 25).
5. With tank drain facing you, take caster foot marked with the letter A (figure 26) and
place in slot on left side of tank also marked with the letter A. Secure with screw provided
(figure 27).
6. Take caster foot marked with the letter B (figure 28) and place in slot on right side of tank
also marked with the letter B. Secure with screw provided (figure 29).
7. Insert casters into feet by placing stem of casters into holes provided. Apply pressure and
twisting motion until casters snap into place (figure 30).
2
8. Return tank to upright position.
9. Place tool basket (not standard with all models) with curved surface against tank on rear
caster dolly assembly (figure 31).
24
28
(Not standard with all models)
If your tool holder looks like the one pictured in figure 32, follow these instructions.
1. With rear of unit facing you, take tool holder and position it with tabs facing rear of unit
(figure 33).
2. Place "J" shaped tabs into the slots on cord wraps (figure 34).
3. Press down until tabs snap into place.
4. Press down on center of tool holder until tab latches on bottom lid (figure 35).
If your tool holder looks like the one pictured in figure 36, follow these instructions.
1. With rear of unit facing you, take tool holder and slide over notches on rear of tank (figure 37).
32
INSTALLING fOAM SLEEVE AND REUSABLE
(Not standard with all models)
WARNING
THE WALL OUTLET BEfORE REMOVING THE TANk COVER.
When using the reusable dry filter to pick up dust and dry
material, you must install foam sleeve and reusable dry
filter to ensure proper filtration. If the vacuum has been
used to pick up liquids, the foam sleeve must be cleaned
B
and dried before installing for dry pick up. With tank cover
in an upside down position, slide foam sleeve down over lid
cage pulling until foam sleeve completely covers lid cage
(figures 38, 39). Center the reusable dry filter on lid cage
(figure 40), slide mounting ring down over filter until ring is
positioned against the ribs of the lid cage (figure 41). The
reusable dry filter should always be in position over the foam
sleeve for dry pick up. To remove the filter for cleaning, remove mounting ring
and filter from lid cage (figure 42). To clean the reusable dry filter, shake off
excess dirt and dust or (depending on the condition of the filter) rinse with water.
Allow the filter to dry completely and re-install. dO nOT mAChIne WASh OR dRy.
INSTALLING THE CARTRIDGE fILTER
(Not standard with all models)
NOTE: If foam sleeve is in position over lid cage, it must be removed before installing cartridge
filter.
The cartridge filter can be used for wet or dry pick up;
installation is the same for both. When picking up large
quantities of liquid please refer to the Wet Pick up Operation
section in this manual. use the cartridge filter in posi-
tion over the lid cage for most general dry material pick
up. With the tank cover in an upside down position, slide
25
26
A
29
30
A
B
B
A

TOOL HOLDER

33
34
36
37

DRy PICk UP

DRy fILTER

– ALWAyS DISCONNECT THE PLUG fROM
27
A
31
35
38
39
40
41
42
43
44