Maintenance
Lubrication
The debris blower has bearings and bushings that must
be lubricated regularly.. If the machine is operated
under normal conditions, lubricate bearings with No. 2
general purpose lithium base grease after every 8 hours
of operation or daily, whichever comes first. Lubricate
fittings immediately after every washing, regardless of
the interval listed.
The lubrication points and quantities are as follows:
Fan shaft–2 (Figure 12)
Figure 12
Castor arm tube (Figure 13)
Castor wheel (Figure 13)
Figure 13
G003730
Greasing the Attachment Adapter
If the locking lever on the attachment adapter does not
pivot freely and easily, apply a light coat of grease to the
area shown in Figure 14.
Bearing Alignment
If the motor mounting brackets are ever removed, they
must be re–aligned before the debris blower is operated.
Refer to the Part Catalog for the Alignment Tool part
number.
1. Make sure the mounting brackets are installed to the
blower housing but capscrews and nuts are loose
(Figure 15).
1
2
1. Alignment tool
2. Mounting bracket
2. Insert the bearing alignment tool through the
mounting brackets and into the fan coupler
(Figure 15). Make sure the spider coupler (Figure 16)
is not in the coupler.
13
G003731
Figure 14
2
3
G003814
Figure 15
3. Fan coupler