Operation

Adjust Discharge Opening

The discharge opening (Figure 9) is adjustable to direct
the air flow from the blower.
1. Loosen discharge opening deflector mounting
screws (Figure 9).
Figure 9
1. Discharge opening
deflector
2. Pivot deflector to desired opening.
3. Tighten mounting screws.

Switch Operation

Lift/Lower Switch (Figure 10) — Move switch to Lift
to raise attachment and to Lower to lower attachment.
Float/Power Down Switch (Figure 10) — Moving the
switch to Float allows the attachment to follow the
contour of the ground. Moving the switch to Power
Down will add weight from the machine to increase
ground engagement force. Higher ground engagement
force will decrease the traction capacity of the machine.
Important: Only run the debris blower in the
FLOAT mode. Never run in the Power Down
mode or damage to the blower will occur.
1
G003812
2
2. Mounting screw
1. Float
2. Power down

Operating Tips

Discharged air has considerable force and could
cause injury or loss of footing.
• Stay away from discharge opening when
machine is operating.
• Keep bystanders away from discharge
opening when machine is running.
• Practice blowing material. It is advisable to blow
the same direction the wind is blowing to prevent
material from blowing back into the cleared area.
• Do not climb curbs with the debris blower mounted
to the machine. Always find a ramp.
Note: If the attachment adapter becomes stuck to the
traction unit adapter, insert a prybar/screwdriver into
the pry slot to disengage the parts (Figure 11).