2.5 — Specifications
Model
Max Generator Size in Watts
UTILITY MAIN breaker, Included
GEN MAIN breaker, included
Branch Circuit Breakers Provided from Factory
Max Load Combined
Max Watts @ 250 Volts
NEMA Type Enclosure
Configuration of Male Inlet
Max 1-pole Circuits* / Max 2-pole Circuits*
Min. gauge Cord Size
Required Main Breaker in load Center (installer pro-
vided)
NOTE: If Ground Fault Circuit Interrupters (GFCI) circuit breakers, Arc Fault Circuit Interrupters, or Surge Protector Circuit Breakers
were used as the branch circuit protector in the main load center, they MUST be used in the transfer switch. Because these circuit
breakers typically take up more than one space, the overall maximum number of circuits may be reduced from the number shown.
2.6 — Planning Your Installation
1. Determine the appliances, circuits or equipment you want to operate with generator power during a power out-
age, such as:
Refrigerator/Freezer
Furnace Blower (gas/oil only)
TV / Radio
Lighting
Water Heater
2. Determine the amps required for each appliance by reading the label on the appliance. IMPORTANT: No appli-
ance should have an amperage rating that exceeds the GEN MAIN breaker rating in the transfer switch (See
Table 1). The total amperage of all circuits can exceed the generator rating, but not all circuits will be able to be
used concurrently.
3. Assign the circuit # in the load center to a circuit (A2, B2, etc.) in the transfer switch matching the size of the cir-
cuit breaker in the load center to the circuit breaker in the transfer switch. Once you've determined which cir-
cuits you want to connect and the appropriate amperage, you will be ready to begin installing your transfer
switch.
4. The location of your load center/electrical panel in your home or business will determine where the transfer
switch will be installed.
6
Table 1: SPECIFICATIONS
6379
7500 rated / 9300 surge
60 Amp
30 Amp
3 – 15 amp 1-pole
3 – 20 amp 1-pole
1 – 20 amp 2-pole
1 – 30 amp 2-pole
30 Amp
7500
NEMA 3R
NEMA L14-30
16 / 8
10/4 wire
2-pole 60 amp
Garage Door Opener
Microwave, Coffee Maker
Well / Septic Pump
Security System
Sump Pump
6381
12500 rated / 15000 surge
100 Amp
50 Amp
3 – 15 amp 1-pole
3 – 20 amp 1-pole
1 – 20 amp 2-pole
1 – 30 amp 2-pole
1 – 50 amp 2-pole
50 Amp
12,500
NEMA 3R
CS6365
16 / 8
6/4 wire
2-pole 100 amp
Computer, Fax and Printer, Phone
Medical Device(s)
Aquarium
Transfer Switch Installation Guidelines