System Messages; Error Messages - Dell PowerEdge T20 Owner's Manual

Hide thumbs Also See for PowerEdge T20:
Table of Contents

Advertisement

System Messages

Error Messages

Error Message
Description
Address mark not
The BIOS found a faulty disk sector or could not find a particular disk sector.
found
Alert! Previous
The system failed to complete the boot routine three consecutive times for the
attempts at
same error. Contact Dell and report the checkpoint code (nnnn) to the support
booting this
technician.
system have failed
at checkpoint
[nnnn]. For help in
resolving this
problem, please
note this
checkpoint and
contact Dell
Technical Support.
Alert! Security
The MFG_MODE jumper has been set and AMT Management features are disabled
override Jumper is
until it is removed.
installed.
Attachment failed
The floppy or hard-drive controller cannot send data to the associated drive.
to respond
Bad command or
Ensure that you have spelled the command correctly, put spaces in the proper
file name
place, and used the correct pathname.
Bad error-
The floppy or hard-drive controller detected an uncorrectable read error.
correction code
(ECC) on disk read
Controller has
The hard drive or the associated controller is defective.
failed
Data error
The floppy or hard drive cannot read the data. For the Windows operating system,
run the chkdsk utility to check the file structure of the floppy or hard drive. For any
other operating system, run the appropriate corresponding utility.
Decreasing
One or more memory modules may be faulty or improperly seated. Re-install the
available memory
memory modules and, if necessary, replace them.
Diskette drive 0
A cable may be loose or the system configuration information may not match the
seek failure
hardware configuration.
8
79

Advertisement

Table of Contents
loading

Table of Contents