Connections - Electrical - Rheem 874 Owner's Manual And Installation Instructions

Gas continuous flow water heater
Table of Contents

Advertisement

All electrical work and permanent wiring must be carried out by a qualified person and in accordance with the
Wiring Rules AS/NZS 3000 and local authority requirements.
Warning: Temperature controllers must not be fitted to this water heater (874 series) as part of a solar
water heater system because water at a temperature much higher than the controller setting can be
delivered. If a solar preheater has been installed to an existing water heater installation, then all controllers
must be disconnected and removed.
The water heater is supplied with a 1.8 metre lead and plug and requires a weatherproof 240 V 50 Hz
general purpose outlet (GPO) to be located within 1.2 metres of the installation. The GPO must be clear of
the flue exhaust, draining water, gas supply pipe and water connections.
The power consumption of the water heater is:
Component
874627 and 872627
The water heater will only operate on a sine wave at 50 Hz. Devices generating a square wave cannot be
used to supply power to the water heater.
CONNECTIONS – ELECTRICAL
Power
consumption
80 Watts
175 Watts
Comments
Burner on, anti frost device inactive
Burner on, anti frost device active
55