3LL/3LK-3
Fullcolor machine
Section
Jam code
DP
70
No original feed
71
An original jam in
the original feed sec-
tion
72
An original jam in
the original convey-
ing section
73
An original jam in
the original registra-
tion section
74
An original jam in
the original feed sec-
tion
75
An original jam in
the original convey-
ing section
76
An original jam in
the original switch-
back section 1
1-4-2
Conditions
The original feed switch (OFSW) does not turn on within
specified time during the first sheet feeding (Retry 5
times).
The original feed switch (OFSW) does not turn on within
specified time during the second sheet feeding (Retry 5
times).
During original tray ascent, the tray upper limit switch
(TULSW) does not turn on within specified time.
The original registration switch (ORSW) does not turn on
within specified time of the original feed switch (OFSW)
turning on.
DP timing switch 1 (DPTSW1) turns off within the speci-
fied time since the switch turns on.
During single scanning, the DP timing switch 1
(DPTSW1) does not turn on within specified time of the
original registration switch (ORSW) turning on (Retry 5
times).
During duplex switchback scanning, the DP timing
switch 1 (DPTSW1) does not turn on within specified
time of the original registration switch (ORSW) turning
on (Retry 5 times).
During dual scanning, the DP timing switch 2 (DPTSW2)
does not turn on within specified time of the original reg-
istration switch (ORSW) turning on (Retry 5 times).
The original feed switch (OFSW) or original registration
switch (ORSW) does not turn off within specified time of
the DP timing switch 1 (DPTSW1) turning on.
Scanning of previous original is not complete when DP
timing switch 1 (DPTSW1) turns on.
During single scanning, the DP timing switch 1
(DPTSW1) does not turn off within specified time of the
original registration switch (ORSW) turning off.
During duplex switchback scanning, the DP timing
switch 1 (DPTSW1) does not turn off within specified
time of the original registration switch (ORSW) turning
off.
During dual scanning, the DP timing switch 2 (DPTSW2)
does not turn off within specified time of the original reg-
istration switch (ORSW) turning off.
During duplex switchback scanning, the switchback tray
switch (SBTSW) does not turn on within specified time of
the DP timing switch 1 (DPTSW1) turning on.
Specified time
40/40 ppm
25/25 ppm
50/40 ppm
30/30 ppm
55/50 ppm
1159 ms
705 ms
1159 ms
705 ms
2 s
2 s
914 ms
557 ms
914 ms
557 ms
1774 ms
1080 ms
1774 ms
1080 ms
1014 ms
617 ms
2084 ms
1268 ms
-
-
1416 ms
862 ms
1416 ms
862 ms
656 ms
400 ms
2318 ms
1411 ms

Hide quick links: