corner of the unit, and lower the belt unit flat inside the
printer.
8.
Turn the two fasteners (5) 90° to the right until they lock. This
will secure the belt unit in place.
9.
Replace the four image drums, complete with their toner
cartridges, into the printer in the same sequence as they came
out: cyan (nearest the rear), magenta, yellow and black
(nearest the front).
10.
Finally, close the top cover and press down firmly at both
sides so that the cover latches closed.

FUSER REPLACEMENT

The fuser is located inside the printer just behind the four image drum
units.
If the printer has recently been powered on, some fuser components
will be very hot. Handle the fuser with extreme care, holding it only by
its handle, which will only be mildly warm to the touch. A warning
label clearly indicates the area. If in doubt, switch the printer off and
wait at least 10 minutes for the fuser to cool before opening the printer
cover.
Switch off the printer and allow the fuser to cool for about 10 minutes
before opening the cover.
WARNING!
REPLACING CONSUMABLE ITEMS > 180