L800/L801
1.4.3 P/S Assy
¸ Removal procedure
1.
Peel off the acetate tape and remove the ferrite core from the groove of the
Housing Lower.
2.
Remove the screw that secures the P/S Assy, and remove the P/S Assy from
the Housing Lower.
Screw
: C.B.P M3x10 (tightening torque: 5-7 kgf.cm)
Housing Lower
Figure 1-40. Removing the P/S Assy
When installing the P/S Assy, put the ferrite core into the groove of
the Housing Lower and secure it with acetate tape as shown in
Fig.1-40.
Whenever the P/S Assy is replaced, the required adjustment must be
A D J U S T M E N T
R E Q U I R E D
carried out.
Refer to "2.1.2 Required Adjustments" (p.74)